Observed intercamera variability in clinically relevant performance characteristics for Siemens Symbia gamma cameras

نویسندگان

  • S. Cheenu Kappadath
  • William D. Erwin
  • Richard E. Wendt
چکیده

We conducted an evaluation of the intercamera (i.e., between cameras) variability in clinically relevant performance characteristics for Symbia gamma cameras (Siemens Medical Solutions, Malvern, PA) based on measurements made using nine separate systems. The significance of the observed intercamera variability was determined by comparing it to the intracamera (i.e., within a single camera) variability. Measurements of performance characteristics were based on the standards of the National Electrical Manufacturers Association and reports 6, 9, 22, and 52 from the American Association of Physicists in Medicine. All measurements were performed using 99mTc (except 57Co used for extrinsic resolution) and low-energy, high-resolution collimation. Of the nine cameras, four have crystals 3/8 in. thick and five have crystals 5/8 in. thick. We evaluated intrinsic energy resolution, intrinsic and extrinsic spatial resolution, intrinsic integral and differential flood uniformity over the useful field-of-view, count rate at 20% count loss, planar sensitivity, single-photon emission computed tomography (SPECT) resolution, and SPECT integral uniformity. The intracamera variability was estimated by repeated measurements of the performance characteristics on a single system. The significance of the observed intercamera variability was evaluated using the two-tailed F distribution. The planar sensitivity of the gamma cameras tested was found be variable at the 99.8% confidence level for both the 3/8-in. and 5/8-in. crystal systems. The integral uniformity and energy resolution were found to be variable only for the 5/8-in. crystal systems at the 98% and 90% confidence level, respectively. All other performance characteristics tested exhibited no significant variability between camera systems. The measured variability reported here could perhaps be used to define nominal performance values of Symbia gamma cameras for planar and SPECT imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Study of Imaging Characteristics of I-125 Imaging Using the Siemens Inveon Scanner and Siemens Symbia TruePoint

Objective: Although Iodine-125 (125I) has been widely used for in vitro studies because of its relatively long half-life (60.1 days), 125I imaging is limited because of its low energy (27 35 keV), even in an animal-dedicated system. In this study, imaging characteristics of 125I were assessed using a small animal-dedicated imaging system and clinical scanner. Methods: Using the Siemens Inveon a...

متن کامل

Intraoperative 3-D mapping of parathyroid adenoma using freehand SPECT

BACKGROUND Freehand single photon emission computed tomography (fSPECT) is a three-dimensional (3-D) tomographic imaging modality based on data acquisition with a handheld detector that is moved freely, in contrast to conventional, gantry-mounted gamma camera systems. In this pilot study, we evaluated the feasibility of fSPECT for intraoperative 3-D mapping in patients with parathyroid adenomas...

متن کامل

Comparison of Effective Dose and Lifetime Risk of Cancer Incidence of Computed Tomography Attenuation Correction Acquisitions and Radiopharmaceutical Administration for Myocardial Perfusion Imaging

Objectives: To measure the organ dose and calculate effective dose from CTAC acquisitions from four commonly used gamma camera SPECT/CT systems. Method: CTAC dosimetry data was collected using thermoluminescent dosimeters on GE's Infinia Hawkeye four and single slice systems, Siemen's Symbia T6 and the Philips Precedence. Organ and effective dose from the administration of 99m Tc-tetrofosmin an...

متن کامل

Evaluation of Performance of Dedicated, Compact Scintillation Cameras

As part of the development of dedicated scintillation cameras, we compared the performances of 2 dedicated cameras with a standard clinical camera (Siemens Orbiter). One dedicated camera was based on a single Position Sensitive Photomultiplier (PSPMT) coupled to a 6 cm by 6 cm by 6 mm NaI(T1) crystal and the other was based on multiplePSPMTs coupled to a 2 mm by 2 mm by 6 mm matrix of NaI(T1) c...

متن کامل

Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams

Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2006