Bore Disruption: An Unusual Mechanical Failure of Two Hip Hemiarthroplasties

نویسندگان

  • Federico Dettoni
  • Umberto Cottino
  • Silvia Spriano
  • Davide Edoardo Bonasia
  • Roberto Rossi
چکیده

We report a case of two hemiarthroplasties (HAs) that underwent an unexpected mechanical failure. Two patients affected by femoral fractures were treated with an HA. At 5 and 7 years after surgery, they showed a breakage of the HA at the head-stem junction. We analyzed macroscopically and microscopically (by a scanning electron microscopy) the surfaces of the broken prostheses. In both cases, a fracture was detected starting at the joining point between the femoral head and the slot that receives the taper cone of the stem (the so-called bore), with the typical macroscopic and microscopic pattern of a fatigue fracture. The fatigue fracture resulted from repeated cycles of torsional stresses throughout the years. In literature, we did not find any other report of such HA failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Author's response to reviews Title: Hemiarthroplasties in young patients with osteonecrosis or a tumour of the proximal femur; an observational cohort study Authors:

Background The failure scenario of total hip arthroplasty (THA) in younger patients (< 65 years) is dependent upon the fixation and wear of the acetabular component. In select cases, where endoprosthetic replacement of the femoral head is unavoidable for limb salvage or functional recovery, hemiarthroplasty is a viable alternative. The purpose of this study was to evaluate hemiarthroplasty as a...

متن کامل

Hemiarthroplasties in young patients with osteonecrosis or a tumour of the proximal femur; an observational cohort study

BACKGROUND The failure scenario in total hip arthroplasty (THA), in younger patients, is dependent on the fixation and wear of the acetabular component. In selected cases, where endoprosthetic replacement of the femoral head is unavoidable for limb salvage or functional recovery, hemiarthroplasty can be chosen as an alternative. The purpose of this study is to evaluate hemiarthroplasty as treat...

متن کامل

Hemiarthroplasties after hip fractures in Norway and Sweden: a collaboration between the Norwegian and Swedish national registries.

National registration of hemiarthroplasties after hip fractures has been established in both Norway and Sweden. We aimed to investigate differences in demographics, choice of implant selection, surgical approaches, and reoperations between the Norwegian Hip Fracture Register (NHFR) and the Swedish Hip Arthroplasty Register (SHAR). As part of the Nordic Arthroplasty Register Association (NARA) p...

متن کامل

More re-operations after uncemented than cemented hemiarthroplasty used in the treatment of displaced fractures of the femoral neck: an observational study of 11,116 hemiarthroplasties from a national register.

Using data from the Norwegian Hip Fracture Register, 8639 cemented and 2477 uncemented primary hemiarthroplasties for displaced fractures of the femoral neck in patients aged > 70 years were included in a prospective observational study. A total of 218 re-operations were performed after cemented and 128 after uncemented procedures. Survival of the hemiarthroplasties was calculated using the Kap...

متن کامل

Total hip replacement after failed hemiarthroplasty or mould arthroplasty. Comparison of results with those of primary replacements.

We compared the radiographic results of secondary total hip replacements, 99 following failed uncemented hemiarthroplasties and 21 following failed mould arthroplasties, with those of 825 primary cemented total hip replacements. The probability of occurrence of a number of radiological changes over time was calculated using survival analysis. The mean follow-up was 7.6 years (range one month to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017