•biomechanics of a Stemless, Metaphyseal Fixation Femoral Design: Effects of Screw Fixation and Interface Conditions
نویسندگان
چکیده
INTRODUCTION: Bone conserving designs, such as hip resurfacings, are an alternative treatment option to conventional total hip arthroplasty (THA) in young, active patients. Previous studies have shown that medullary fixation can result in significant proximal bone resorption through stress shielding [1,2], while it has been suggested that hip resurfacing arthroplasty will load the proximal femoral bone in a more physiological manner [2,3]. Metaphyseal fixation has been proposed as a solution for preserving proximal bone stock, while minimizing bone resorption induced by medullary fixation [4]. The stemless Munting hip is an example of a design that relies on proximal metaphyseal fixation (Fig. 1) [4,5]. The hydroxyapatite-coated implant has no intramedullary stem and fits into an angular resection of the femoral neck. The component has five lamellae that fit into the metaphyseal cancellous bone, while two trans-trochanteric screws and a distal screw provide initial fixation in place of bone cement. Although in vitro experiments of the Munting hip have been performed previously [4], the effects of screw fixation and interface conditions have not been fully described. The goal of our study was to develop a three dimensional FE model of the implanted femur to examine the effects of screw fixation and boneimplant interface conditions on femoral stresses, strains, and remodeling and to determine if these data support the concept of metaphyseal fixation.
منابع مشابه
Erratum to: High incidence of periprosthetic joint infection with propionibacterium acnes after the use of a stemless shoulder prosthesis with metaphyseal screw fixation - a retrospective cohort study of 241 patients propionibacter infections after eclipse TSA
Erratum After the publication of the article [1] is was brought to our attention that the title was incorrectly given as “High incidence of periprosthetic joint infection with propionibacterium acnes after the use of a stemless shoulder prosthesis with metaphyseal screw fixation a retrospective cohort study of 241 patients propionibacter infections after eclipse TSA”. The correct title is “High...
متن کاملBiomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملBone Graft Substitute Provides Metaphyseal Fixation for a Stemless Humeral Implant.
Stemless humeral fixation has become an alternative to traditional total shoulder arthroplasty, but metaphyseal fixation may be compromised by the quality of the trabecular bone that diminishes with age and disease, and augmentation of the fixation may be desirable. The authors hypothesized that a bone graft substitute (BGS) could achieve initial fixation comparable to polymethylmethacrylate (P...
متن کاملBiomechanics of locked plates and screws.
OBJECTIVE To review the biomechanical principles that guide fracture fixation with plates and screws; specifically to compare and contrast the function and roles of conventional unlocked plates to locked plates in fracture fixation. We review basic plate and screw function, discuss the design rationale for the new implants, and examine the biomechanical evidence that supports the use of such im...
متن کاملThe influence of stem length and fixation on initial femoral component stability in revision total knee replacement
OBJECTIVES Orthopaedic surgeons use stems in revision knee surgery to obtain stability when metaphyseal bone is missing. No consensus exists regarding stem size or method of fixation. This in vitro study investigated the influence of stem length and method of fixation on the pattern and level of relative motion at the bone-implant interface at a range of functional flexion angles. METHODS A c...
متن کامل