In vivo microelectrode track reconstruction using magnetic resonance imaging.

نویسندگان

  • S H Fung
  • D Burstein
  • R T Born
چکیده

To obtain more precise anatomical information about cortical sites of microelectrode recording and microstimulation experiments in alert animals, we have developed a non-invasive, magnetic resonance imaging (MRI) technique for reconstructing microelectrode tracks. We made microelectrode penetrations in the brains of anesthetized rats and marked sites along them by depositing metal, presumably iron, with anodic monophasic or biphasic current from the tip of a stainless steel microelectrode. The metal deposits were clearly visible in the living animal as approximately 200 microm wide hypointense punctate marks using gradient echo sequences in a 4.7T MRI scanner. We confirmed the MRI findings by comparing them directly to the postmortem histology in which the iron in the deposits could be rendered visible with a Prussian blue reaction. MRI-visible marks could be created using currents as low as 1 microA (anodic) for 5 s, and they remained stable in the brains of living rats for up to nine months. We were able to make marks using either direct current or biphasic current pulses. Biphasic pulses caused less tissue damage and were similar to those used by many laboratories for functional microstimulation studies in the brains of alert monkeys.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging

Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....

متن کامل

Innovative Methodology High-Resolution Three-Dimensional Microelectrode Brain Mapping Using Stereo Microfocal X-ray Imaging

Cox DD, Papanastassiou AM, Oreper D, Andken BB, DiCarlo JJ. High-resolution three-dimensional microelectrode brain mapping using stereo microfocal X-ray imaging. J Neurophysiol 100: 2966–2976, 2008. First published September 24, 2008; doi:10.1152/jn.90672.2008. Much of our knowledge of brain function has been gleaned from studies using microelectrodes to characterize the response properties of ...

متن کامل

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

3D imaging using magnetic resonance tomosynthesis (MRT) technique.

PURPOSE To introduce an alternative approach to three-dimensional (3D) magnetic resonance (MR) imaging using a method that is similar to x-ray tomosynthesis. METHODS Variable angle tilted-projection images are acquired using a multiple-oblique view (MOV) pulse sequence. Reconstruction is performed using three methods similar to that of x-ray tomosynthesis, which generate a set of tomographic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neuroscience methods

دوره 80 2  شماره 

صفحات  -

تاریخ انتشار 1998