Refractive Predictability of Partial Coherence Interferometry and Factors that can Affect It

نویسندگان

  • Seung Mo Kim
  • Joohyun Choi
  • Sangkyung Choi
چکیده

PURPOSE To evaluate the refractive predictability of a partial coherence interferometry (PCI) biometry device (IOL Master) for cataract surgery and to investigate factors that may affect it. METHODS Retrospective review of 209 eyes from 151 patients that had undergone preoperative PCI biometry and an uneventful phacoemulsification cataract surgery with posterior chamber intraocular lens (IOL) implantation was conducted. Prediction error defined as the intended refraction minus the postoperative refraction in spherical equivalent (SE) and the absolute error were analyzed according to IOL calculation formulas, patient characteristics, preoperative visual acuity (VA) and refraction, posterior subcapsular cataract (PSC), signal-to-noise ratio (SNR), and axial length (AL). RESULTS The overall refractive predictability of the PCI device was good. Generally, the SRK/T formula performed better than the SRK-II formula. Refractive predictability was slightly worse in eyes with >or=+2.0 diopters (D) of preoperative SE (with both SRK-II and SRK/T) and in eyes with an ALor=+2.0D was related to a significantly greater hyperopic shift in postoperative refraction. With proper verification of measured data and a suitable IOL calculation formula, good refractive predictability is expected from PCI biometry regardless of patient characteristics, preoperative VA, SNR, PSC, and AL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Estimation of Earthquake Damage Through Radar Interferometry (Case study: Bam 2003 Earthquake)

The estimate of the damage caused by the earthquake and other natural disasters in the first days after the occurrence of these events can provide a quick damages assessment and help to manage the crisis. Several methods are available to investigate the extent of earthquake’s damage. Optical remote sensing, photogrammetric methods (UAVs and LIDARs), radar interferometry (InSAR) and field observ...

متن کامل

Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

PURPOSE To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). SETTING Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Pa...

متن کامل

Immersion A-scan compared with partial coherence interferometry: outcomes analysis.

PURPOSE To compare 2 methods of axial length measurement, immersion ultrasonography and partial coherence interferometry, and to elucidate surgical outcomes based on immersion measurements. SETTING Oregon Eye Institute, Eugene, Oregon, USA. METHODS Axial length measurements in 50 cataractous eyes were obtained by optical biometry (IOLMaster, Zeiss Humphrey Systems) and immersion ultrasound ...

متن کامل

Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included...

متن کامل

ذخیره در منابع من