Raman-shifted alexandrite laser for soft tissue ablation in the 6- to 7-µm wavelength range

نویسندگان

  • John Kozub
  • Borislav Ivanov
  • Aroshan Jayasinghe
  • Ratna Prasad
  • Jin Shen
  • Marc Klosner
  • Donald Heller
  • Marcus Mendenhall
  • David W. Piston
  • Karen Joos
  • M. Shane Hutson
چکیده

Prior work with free-electron lasers (FELs) showed that wavelengths in the 6- to 7-µm range could ablate soft tissues efficiently with little collateral damage; however, FELs proved too costly and too complex for widespread surgical use. Several alternative 6- to 7-µm laser systems have demonstrated the ability to cut soft tissues cleanly, but at rates that were much too low for surgical applications. Here, we present initial results with a Raman-shifted, pulsed alexandrite laser that is tunable from 6 to 7 µm and cuts soft tissues cleanly-approximately 15 µm of thermal damage surrounding ablation craters in cornea-and does so with volumetric ablation rates of 2-5 × 10(-3) mm(3)/s. These rates are comparable to those attained in prior successful surgical trials using the FEL for optic nerve sheath fenestration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implications of laser light characteristics on the Raman signal-to-noise ratio in diagnostic analysis of glioblastoma multiforme

The presented work is part of a study investigating the surgical diagnostic potential of Raman spectroscopy for the malignant brain tumor, glioblastoma multiforme (GBM). This work examines the trade-off of increased Raman signal observed using excitation at lower wavelengths (1/X4 signal dependence) versus the fluorescence caused by endogenous tissue fluorophores at those wavelengths. Within th...

متن کامل

Wavelength-dependent collagen fragmentation during mid-IR laser ablation.

Mid-infrared free-electron lasers have proven adept in surgical applications. When tuned to wavelengths between 6 and 7 microm, such lasers remove defined volumes of soft tissue with very little collateral damage. Previous attempts to explain the wavelength-dependence of collateral damage have invoked a wavelength-dependent loss of protein structural integrity. However, the molecular nature of ...

متن کامل

Study of laser ablation using nano-second laser pulses

 In this paper, the laser ablation process based on the irradiation of nanosecond pulsed lasers on a copper target surface in the presence of Helium gas is studied. The dynamical behaviors of the generated plasma in the helium gas and evaporated copper at the atmospheric pressure are examined using a laser pulse, laser wavelength of and intensity of 7×1010W/cm2. A one-dimensional thermal model ...

متن کامل

Observation of Raman Gain in Reduced Length of Bismuth Erbium Doped Fiber

Raman amplification of a 49 cm Bismuth oxide (Bi2O3) as a nonlinear gainmedium based erbium doped fiber amplifier (EDFA) is reported in new and compactdesign in near infrared spectral regions. The bismuth glass host provides theopportunity to be doped heavily with erbium ions to allow a compact optical gain fiberamplifier design by using reduced fiber length and the 1480...

متن کامل

Comparison of Soft Tissue Thermal Changes Induced by Three Types of Diode Lasers at 810, 940, and 980nm Wavelengths

Background and Aim: Diode laser is a great choice for soft tissue surgery. The diode laser is partially absorbed by hard dental tissues, making it safe for soft tissue surgery. This study aimed to compare the tissue thermal changes induced by three types of diode lasers at 810, 940, and 980nm wavelengths. Materials and Methods: In this in-vitro experimental study, using a diode laser device (c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2011