Stability of Etoposide Solutions in Disposable Infusion Devices for Day Hospital Cancer Practices

نویسندگان

  • Alison Klasen
  • Romain Kessari
  • Lionel Mercier
  • Cyril Valade
  • Jacques Grill
  • Romain Desmaris
  • Angelo Paci
چکیده

In a context of day hospital care of cancer patients, a protocol combining etoposide and carboplatin is used in paediatrics. Disposable infusion devices can be used to improve patient quality of life and to optimize nursing time. Stability data are available for carboplatin in these devices but not for etoposide. The aim of this study was to determine the stability of etoposide solutions in these devices by monitoring the changing etoposide concentration. To study the changing etoposide concentration, we investigated three different concentrations, each in two different solvents: sodium chloride (NaCl) 0.9 % and dextrose 5 %, in Intermate(®) disposable infusion devices. Quantitative analyses were performed by high-performance liquid chromatography coupled with ultraviolet (UV) detection on samples collected over a 24-h study period. The results showed that 100 mg/L etoposide solutions were stable for 24 h in NaCl 0.9 % and for 12 h in dextrose 5 %, whatever the temperature. The 400-mg/L solutions were stable for 24 h in both diluents, whatever the temperature, whereas the 600-mg/L solutions when diluted in NaCl 0.9 % and dextrose 5 % in water were stable for 8 and 6 h, respectively. We found that precipitation was the main phenomenon responsible for decreased etoposide concentrations. This study allowed us to conclude that etoposide solutions prepared in Intermate(®) infusion devices are stable for day hospital administration in paediatrics. It will also allow us to conduct a future clinical study that will focus on the medico-economic feasibility of this protocol and on the evaluation of patient and nurse satisfaction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fortum stability in different disposable infusion devices by pyridine assay.

The stability of ceftazidime in 5% dextrose injection and 0.9% sodium chloride injection when stored in a different disposable infusion device was determined. Solutions of ceftazidime 40 mg/ml were used to fill the drug administration devices. Stability was determined for both 5% dextrose injection and 0.9% sodium chloride injection solutions at 37 degrees C in four disposable infusion devices....

متن کامل

Stability of commonly used antibiotic solutions in an elastomeric infusion device.

BACKGROUND The Accufuser silicone-based elastomeric infusion device has recently been approved for the Canadian market. OBJECTIVE To evaluate the stability of 5 antibiotics (cefazolin, ceftazidime, ceftriaxone, clindamycin, and vancomycin) in either 5% dextrose in water (D5W) or 0.9% sodium chloride in water (NS) after storage in Accufuser disposable silicone balloon infusers. METHODS The s...

متن کامل

LONG TERM ORAL ETOPOSIDE AS SECOND-LINE THERAPY IN RECURRENT EPITHELIAL CARCINOMA OF THE OVARY

Background: The activity and toxicity of etoposide in women with recurrent ovarian cancer was evaluated in a case series of women with recurrent ovarian cancer who had measurable disease, Methods: All patients had plior platinum-based chemotherapy and developed progressive disease, Etoposide was given as 50mg/day for 21 days every 4 weeks until progression of disease or prohibitive toxicit...

متن کامل

An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital

Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...

متن کامل

An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital

Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014