Radioimmunoassay of methaqualone in human urine compared with chromatographic methods.

نویسندگان

  • S J Mulé
  • M Kogan
  • D Jukofsky
چکیده

The 125I-radioimmunoassay for methaqualone in human urine was evaluated by a comparison with newly modified gas-liquid chromatographic and thin-layer chromatographic methods. The statistically significant sensitivity value for the radioimmunoassay was at 2 microgram of methaqualone per liter of urine. The coefficient of variation was 2.88 +/- 0.39% interassay and 2.71 +/- 0.16% intraassay. There was cross-reactivity only with metabolites of methaqualone, 4'-hydroxymethaqualone being twice as sensitively measured as methaqualone. There was complete agreement between results by radioimmunoassay and by gas-liquid chromatography in 96.7% of the samples analyzed. Only 1.2% of the radioimmunoassay values were false positives, and 2.1% false negatives (phi = 0.8917, P less than 0.001). Comparisons between the thin-layer chromatographic data and the gas-liquid chromatographic or radioimmunoassay data showed less agreement because of the 50- to 200-fold higher sensitivity of the latter two techniques. Gas-liquid chromatography therefore appears to represent the best reference method for the evaluation of the radioimmunoassay, which appears to be a very sensitive and reliable technique for detecting methaqualone and its metabolites in human urine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radioimmunoassay of methaqualone and its monohydroxy metabolites in urine.

A commercial radioimmunoassay kit was evaluated for efficacy in detecting methaqualone or its metabolites in urine of persons receiving this drug. The drug and its unconjugated 3'- and 4'-monohydroxy metabolites could be detected equally well. The unconjugated alpha-monohydroxy metabolite was about 80% as reactive and the unconjugated 6-monohydroxy metabolite reacted only very weakly. Quantitat...

متن کامل

DEVELOPMENT OF A RAPID AND SENSITIVE RADIOIMMUNOASSAY FOR MEASUREMENT OF AFLATOXIN B 1 IN BIOLOGICAL SAMPLES

Aflatoxin B I (AFB) isa well known hepatocarcinogen in several animal species and probably a causative agent in human hepatocellular carcinoma. Humans are exposed to AFB by ingesting contaminated food. Aflatoxin contamination encountered in human foods is usually at low levels which is difficult to measure by chromatographic methods. Therefore in the present study we have developed an immun...

متن کامل

Radioimmunuassay compared to thin-layer and gas--liquid chromatography for detecting methadone in human urine.

Radioimmunoassay was compared to thin-layer and gas--liquid chromatographic methods for detection of methadone in the urine of patients undergoing methadone maintenance therapy as treatment of heroin abuse. With urine samples known to contain methadone, 84% were positive by thin-layer chromatography as compared to 99% positives by the other two methods. This difference is attributed to the diff...

متن کامل

Oxybuprocaine and five metabolites simultaneously determined in urine by gas chromatography and gas chromatography-mass spectrometry after extraction with Extrelut.

We describe a gas-liquid chromatographic (GC) method for determination of oxybuprocaine, and a gas chromatographic-mass spectrometric (GC-MS) method for simultaneous determination of four of its nine metabolites in urine. We used an Extrelut column to simply and rapidly extract oxybuprocaine and its metabolites from urine. For the GC-MS analyses, we monitored the characteristic fragment ions at...

متن کامل

Non-chromatographic radioimmunoassay procedure for urinary aldosterone.

We describe a sensitive, specific, and simple procedure for measuring aldosterone in human urine, which requires no chromatographic purification before quantification by radioimmunoassay but does include hydrolysis and extraction steps. Rabbit anti-aldosterone serum is sued, generated against aldosterone-18,21-dihemisuccinate coupled to human serum albumin. The antibody cross reacted little wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 9  شماره 

صفحات  -

تاریخ انتشار 1978