On-the-Fly Motion-Compensated Cone-Beam CT Using an a Priori Motion Model

نویسندگان

  • Simon Rit
  • Jochem Wolthaus
  • Marcel van Herk
  • Jan-Jakob Sonke
چکیده

Respiratory motion causes artifacts in slow-rotating cone-beam (CB) computed tomography (CT) images acquired for example for image guidance of radiotherapy. Respiration-correlated CBCT has been proposed to correct for the respiratory motion, but the use of a subset of the CB projections to reconstruct each frame of the 4D CBCT image limits their quality, thus requiring a longer acquisition time. Another solution is motion-compensated CBCT which consists of reconstructing a single 3D CBCT image at a reference position from all the CB projections by using an estimate of the respiratory motion in the reconstruction algorithm. In this paper, we propose a method for motion-compensated CBCT which allows to reconstruct the image on-the-fly, i.e. concurrent with acquisition. Before the CB acquisition, a model of the patient motion over the respiratory cycle is estimated from the planning 4D CT. The respiratory motion is then computed on-the-fly from this model using a respiratory signal extracted from the CB projections and incorporated into the motion-compensated CBCT reconstruction algorithm. The proposed method is evaluated on 26 CBCT scans of 3 patients acquired with two protocols used for static and respiration-correlated CBCT respectively. Our results show that this method provides CBCT images within a few seconds after the end of the acquisition where most of the motion artifacts have been removed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Motion-Compensated Cone Beam CT Using a Conjugate Gradient Least Squares Algorithm and EIT Imaging Motion Data

Cone Beam Computed Tomography (CBCT) is an imaging modality that has been used in image-guided radiation therapy (IGRT). For applications such as lung radiation therapy, CBCT images are greatly affected by the motion artefacts. This is mainly due to low temporal resolution of CBCT. Recently, a dual modality of Electrical Impedance Tomography (EIT) and CBCT has been proposed, in which the high t...

متن کامل

2D/3D Registration for Motion Compensated Reconstruction in Cone-Beam CT of Knees Under Weight-Bearing Condition

Over the last decade, increased effort has been made to acquire three dimensional images of knee joints under weight-bearing condition. Cone-beam CT systems are popular because of their high flexibility with respect to patient position and scan trajectory. However, scans in a standing or squatting patient position are affected by involuntary patient motion during the acquisition, which results ...

متن کامل

Motion-compensated iterative cone-beam CT image reconstruction with adapted blobs as basis functions.

This paper presents a three-dimensional method to reconstruct moving objects from cone-beam X-ray projections using an iterative reconstruction algorithm and a given motion vector field. For the image representation, adapted blobs are used, which can be implemented efficiently as basis functions. Iterative reconstruction requires the calculation of line integrals (forward projections) through t...

متن کامل

Respiratory Motion Estimation from Cone-Beam Projections Using a Prior Model

Respiratory motion introduces uncertainties when planning and delivering radiotherapy for lung cancer patients. Cone-beam projections acquired in the treatment room could provide valuable information for building motion models, useful for gated treatment delivery or motion compensated reconstruction. We propose a method for estimating 3D+T respiratory motion from the 2D+T cone-beam projection s...

متن کامل

A dual modality of cone beam CT and electrical impedance tomography for lung imaging

Electrical impedance tomography (EIT) is a new and emerging tomographic imaging system, which is able to provide high temporal resolution with low spatial resolution. In past few years, the EIT has been extensively studied for lung monitoring. Cone beam CT (CBCT) is an imaging system used in radiation therapy unit. The CBCT suffers from motion artefacts, making treatment planning inaccurate. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 11 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2008