Image Quality Enhancement in X-Ray Microscopy

نویسندگان

  • J.-B. Sibarita
  • J. Lehr
  • J.-M. Chassery
  • M. Robert-Nicoud
  • P. Guttmann
  • G. Schmahl
چکیده

The goal of this work is to develop digital image processing tools for improving the quality of the images provided by the Göttingen transmission X-ray microscope at BESSY [1, 2]. We first present a method for correcting the inhomogeneous illumination. Then, we present results of image restoration techniques applied to X-ray microscopy images of test objects and of biological specimens containing specific gold probes. Since this restoration process requires knowledge of the point spread function (PSF), we propose a handy method for the measurement of the line spread function (LSF) of the optical system, which can be used as an estimate of the point spread function. Finally, we show the results of applying noise reduction procedures on images of biological specimens. 1 PSF Estimation The knowledge of the PSF is needed for the restoration process. We developed a method for PSF-estimation based on the measurement of the ESF (Edge Spread Function). A gold edge obtained by cutting a gold covered polyimide foil is used as a test-object. To avoid problems with noise, we fit an empirically found function which models the ESF with sufficient precision. The model function we propose is the following : ( ) ESF a a a a a a a a A B ( ) exp( ( )) ( ) exp( ( )2) ( ) ( ) x x x x x x = + + − − + − − − = + 0 1

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image quality enhancement in digital panoramic radiograph

One of the most common positioning errors in panoramic radiography is palatoglossal air space above the apices of the root of maxillary teeth. It causes a radiolucency obscuring the apices of maxillary teeth. In the case of this positioning error, the imaging should be repeated. This causes the patient be exposed to radiation again. To avoid the repetition of exposing harmful X-rays to the pati...

متن کامل

Evaluation of the effect of four current Iranian processing solutions on the image quality of two dental X-ray films

Evaluation of the effect of four current Iranian processing solutions on the image quality of two dental X-ray films Dr. M. Imani Moghadam* - Dr. AHA. Afzali** - Eng. S. Ebrahim Zadeh*** *- Assistant Professor of Dentomaxillofacial Radiology Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Radiologist. ***- The member of Mashhad University of Medical Sciences. Backgrou...

متن کامل

Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...

متن کامل

Combine flake like magnesium hydroxide and cubic like aluminum hydroxide nanostructures in order to improve fire retardant of PVC and PMMA

In this study, Flake-like magnesium hydroxide (Mg(OH)2) and cubic-like aluminum hydroxide (Al(OH)3) nanostructures were synthesized via a simple co-precipitation method at relatively low temperature. Chemical properties and surface morphology of the magnesium hydroxide and aluminum hydroxide were characterized by X-ray diffraction analysis (XRD), scanning electron microscopy image (SEM), transm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998