چکیده

This paper provides an analysis of the real-time behaviour of the multimaster Profibus DP network. The analysis is based on the evaluation of the worstcase message response time and the results obtained are compared with those present in literature, pointing out its capability to perform a more accurate evaluation of the performance of the Profibus network. Copyright © 2002 IFAC

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating Worst Case Response Time in Mono and Multi-master Profibus Dp

Profibus networks are often used as the communication infrastructure for supporting distributed computer-controlled applications. Very often these applications impose strict real-time requirements. A widely used class of Profibus networks is the Profibus-DP profile, which may be implemented as mono or multi-master network. The aim of this paper is to analyse the real-time behaviour of both mono...

متن کامل

Designing Real-time Systems Based on Mono-master Profibus-dp Networks

Profibus networks are widely used as the communication infrastructure for supporting distributed computer-controlled applications. Most of the times, these applications impose strict real-time requirements. Profibus-DP has gradually become the preferred Profibus application profile. It is usually implemented as a mono-master Profibus network, and is optimised for speed and efficiency. The aim o...

متن کامل

An experimental approach to estimate real-time characteristic of PROFINET IO versus PROFIBUS DP V2

This paper investigates performances of PROFINET IO Class 1, based on Ethernet@100Mbit/s, as a replacement of PROFIBUS DP V2, based on RS485 @ 12Mbit/s, for the realization of time-critical and isochronous systems. In this work, two test systems have been built. In the first one, the same experimental setup with the same application has been implemented using PROFINET and PROFIBUS networks and ...

متن کامل

From Task Scheduling in Single Processor Environments to Message Scheduling in a PROFIBUS Fieldbus Network

In this paper we survey the most relevant results for the priority-based schedulability analysis of real-time tasks, both for the fixed and dynamic priority assignment schemes. We give emphasis to the worst-case response time analysis in non-preemptive contexts, which is fundamental for the communication schedulability analysis. We define an architecture to support priority-based scheduling of ...

متن کامل

Guaranteeing real-time message deadlines in PROFIBUS networks

Profibus is based on a simplified Timed Token (TT) protocol, which is a well-proved solution for real-time communication systems. However, Profibus differences to the TT protocol prevent the application of the usual TT analysis. The main reason is that, conversely to the TT protocol, in the worst case, only one high-priority message is processed per token visit. The major contribution of this p...