[Application of collimator broad correction three dimensional ordered subsets expectation maximization for regional cerebral blood flow measurement].

نویسندگان

  • Mami Okada
  • Masuo Hayashi
  • Hisashi Tsuji
  • Hiroyuki Akagi
  • Katsuyoshi Okayama
  • Yoshifumi Narumi
چکیده

Autoradiography (ARG) has been used for quantitative analysis of the cerebral blood flow using 123I-IMP, and the regional cerebral blood flow (rCBF) can be assessed more accurately with scatter and attenuation correction. Currently, the filtered back projection (FBP) method is generally used for image reconstruction. However, we anticipate obtaining more accurate rCBF by the ordered subsets expectation maximization method with collimator broad correction three dimensional ordered subsets expectation maximization (3D-OSEM). In the present study, we optimized the processing conditions to quantify rCBF using the 3D-OSEM method and compared them with the FBP method. Regarding the method, we determined the subsets and iteration, compared rCBF values using a profile curve, and compared them with the rCBF values obtained by the XeCT (Xenon-enhanced computed tomography)/CBF method. We found that in the 3D-OSEM method using 90 direction collection and 1.72 mm/pixel, the most accurate image was obtained around subset 9 and iteration 10. In addition, as compared to the profile curve and the XeCT/CBF method, the thalamus rCBF was high in the 3D-OSEM method with a good correlation with that of the XeCT/CBF. Accordingly, we concluded that the 3D-OSEM method can improve the decrease in rCBF due to blurring of the distance between the source (i.e., a structure located in the central part of the brain such as the thalamus and the collimator).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom

Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...

متن کامل

Impact of reconstruction method on quantitative parameters of 99mTc-TRODAT-1 SPECT

Introduction: Quantitative evaluation is recommended to improve diagnostic ability and serial assessment of dopamine transporter (DAT) density scans. We decided to compare the ordered subsets expectation-maximization (OSEM) with filtered back-projection (FBP), and to investigate the impact of different iteration and cut-off frequencies on SBR values. Methods</stro...

متن کامل

Reliability and advantages of using non-uniform Chang’s attenuation correction method using a CT-based attenuation coefficient map in 99mTc-GSA SPECT/CT hepatic imaging

BACKGROUND Generally, attenuation correction is made by incorporating a linear attenuation coefficient, which is based on the attenuation coefficient map (mu-map) created from a computed tomography scan, into the ordered subsets-expectation maximization reconstruction method in non-uniform domains. A non-uniform Chang's attenuation correction method that uses the mu-map created from a computed ...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 68 5  شماره 

صفحات  -

تاریخ انتشار 2012