Temperature dependence of dark current in a CCD
نویسندگان
چکیده
We present data for dark current of a back-illuminated CCD over the temperature range of 222 to 291 K. Using an Arrhenius law, we found that the analysis of the data leads to the relation between the prefactor and the apparent activation energy as described by the Meyer-Neldel rule. However, a more detailed analysis shows that the activation energy for the dark current changes in the temperature range investigated. This transition can be explained by the larger relative importance at high temperatures of the diffusion dark current and at low temperatures by the depletion dark current. The diffusion dark current, characterized by the band gap of silicon, is uniform for all pixels. At low temperatures, the depletion dark current, characterized by half the band gap, prevails, but it varies for different pixels. Dark current spikes are pronounced at low temperatures and can be explained by large concentrations of deep level impurities in those particular pixels. We show that fitting the data with the impurity concentration as the only variable can explain the dark current characteristics of all the pixels on the chip.
منابع مشابه
Entropy-Based Dark Frame Subtraction
Noise due to dark current is a serious limitation for taking long exposure time images with a CCD digital camera. Current solutions have serious drawbacks: interpolation of pixels with high dark current leads to smoothing effects or other artifacts – especially if a large number of pixels are corrupted. Due to the exponential temperature dependence of the dark current, dark frame subtraction wo...
متن کاملINSTITUTE Instrument Science Report STIS 2009 - 02 STIS CCD Performance after SM 4 : Read Noise , Dark Current , Hot Pixel Annealing , CTE , Gain , and Spectroscopic Sensitivity
We describe the overall performance of the STIS CCD after HST Servicing Mission #4 and the associated updates to calibration reference files. Most aspects of CCD performance are found to be fairly consistent with extrapolations of the trends seen prior to the failure of STIS in August 2004. The CCD gain value for the CCDGAIN = 4 setting has been redetermined using net count ratios of standard s...
متن کاملThe perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs
Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...
متن کاملImpressive Reduction of Dark Current in InSb Infrared Photodetector to achieve High Temperature Performance
Infrared photo detectors have vast and promising applications in military,industrial and other fields. In this paper, we present a method for improving theperformance of an infrared photodetector based on an InSb substance. To achieve goodperformance at high temperatures, thermal noise and intrusive currents should bereduced. For this purpose, a five-layer hetero structu...
متن کاملWFC3 Ambient Testing: UVIS Dark Current Rate
Ground testing of WFC3 under ambient conditions during April of 2007 was performed in order to prepare for upcoming thermal vacuum testing. As a part of this ambient testing, the dark current rate of the spare UVIS package (UVIS build 2) was measured while the CCD was operating at a temperature of -54oC. This temperature is significantly higher than the nominal operating temperature of -83oC, l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003