Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd Seeds
نویسندگان
چکیده
BACKGROUND A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC) is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet. OBJECTIVE The present study aims to modify source strength for different configurations of 125I and 103Pd seeds used in lung permanent implant brachytherapy. METHODS Different arrays of 125I and 103Pd seeds were simulated by MCNPX code in protocol-based water vs. actual 3D lung environments. Absorbed dose was, then, scored in both mediums. Dose differences between both environments were calculated and source strength was modified for the prescription point. In addition, lung-to-water absorbed dose ratio was obtained and presented by precise equations. RESULTS Due to significant differences in prescription dose, source strength was modified 16%-19% and 37%-43% for different configurations of 125I and 103Pd seeds, respectively. In addition, depth-dependent dose differences were observed between the actual lung and protocol-based water mediums (dose difference as a function of depth). CONCLUSION Modification of source strength is essential for different arrangements of 125I and 103Pd seeds in lung implantation. Modified source strength and presented equations are recommended to be considered in future studies based on lung brachytherapy.
منابع مشابه
Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds
Background:Â A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective:Â The present study aims to modify source strength for different configurations of 125I and 103...
متن کاملThe Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds
Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...
متن کاملDetermination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source
Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...
متن کاملDetermination of TG-43 Dosimetric Parameters for Photon Emitting Brachytherapy Sources
Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...
متن کاملUsing PSO algorithm optimization for planning 103Pd seeds brachytherapy positions
Radiation therapy, is one of the treatments for cancer. Brachytherapy is a radiotherapeutic technique that a sealed radiation source is placed inside or next to the tissue and has become a mainstream treatment option for cancer. Achieving maximum dose to the gland as well as minimum injury to the adjacent tissues is a basic principle in radiation therapy. Sources configuration must be designed ...
متن کامل