Evaluation of Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma.

نویسندگان

  • Halil Ates
  • Melis Palamar
  • Ayse Yagci
  • Sait Egrilmez
چکیده

PURPOSE To evaluate the intraocular pressure (IOP) control and graft survival after Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma. METHODS The study included postpenetrating keratoplasty glaucoma cases unresponsive to medical antiglaucomatous therapy in whom 15 Ex-PRESS mini glaucoma shunt implantation was carried out. All glaucoma shunt implantations were performed in a separate session after penetrating keratoplasty. Nine operations were performed under general anesthesia and 6 were performed under local anesthesia. Topical antibiotherapy and topical corticosteroids were used during the postoperative first month. RESULTS Mean age of the study population was 37.4 years (range: 10 to 80 y). IOP decreased from 41.46 mm Hg (range: 26 to 80 mm Hg) to 12.06 mm Hg (range: 8 to 25 mm Hg) over a mean follow-up of 12.2 months (range: 8 to 19 mo) (P<0.001; Wilcoxon signed rank test). IOP was below 21 mm Hg in 14 of 15 eyes (93.3%) with or without antiglaucomatous drugs. Complete success (IOP<21 mm Hg without medication) rate was 86.6%. Average number of antiglaucomatous drug usage decreased from 3.20 (range: 2 to 4) preoperatively to 0.26 postoperatively (range: 0 to 3) (P<0.001; Wilcoxon signed rank test). In 93.3% of the cases, the decrease in IOP was 30% or above postoperatively. After Ex-PRESS implantation, clear grafts remained clear while edematous grafts became clearer due to IOP decrease. Neither biomicroscopy nor pachymetry showed worsening of preoperatively opaque grafts. CONCLUSION Ex-PRESS mini glaucoma shunt implantation may be an effective procedure for refractory postpenetrating keratoplasty glaucoma with acceptable graft failure rates in short term.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical experience with Ex-press Mini Glaucoma Shunt implantation.

In this prospective study we wanted to report our experience and to evaluate the efficacy and safety of Ex-press Mini-Glaucoma Shunt implantation under a superficial scleral flap, as a newly and improved surgical technology in a treatment of POAG (Primary open-angle glaucoma) and refractory glaucoma. 44 eyes (35 patients) underwent an implantation of Ex-Press Mini Glaucoma Shunt. We had 21 pati...

متن کامل

Ex-PRESS miniature glaucoma shunt in treatment of refractory glaucoma.

Refractory glaucoma in a complicated type of glaucoma of different ethyologies with one same characteristic--intraocular pressure of great resistance to therapy. There are different methods of treatment in such glaucomas, primary surgical options. Ex-PRESS miniature glaucoma shunt implantation was our treatment of choice. In our group of patients we achieved stabile intraocular pressure values ...

متن کامل

Glaucoma after Penetrating Keratoplasty: Incidence, Risk Factors, and Management

Purpose. To report the incidence and risk factors for postkeratoplasty glaucoma (PKG), as well as its management. Subjects and Methods. 122 eyes, (43% with pseudophakic and aphakic bullous keratopathy (PABK)) which underwent penetrating keratoplasty (PK), were analyzed. Results. The rate of PKG development was 34% within 39 months of follow-up. PABK, corneal perforations, keratitis, and previou...

متن کامل

A comparison of the Ex-PRESS™ mini glaucoma shunt with standard trabeculectomy in the surgical treatment of glaucoma.

BACKGROUND AND OBJECTIVE To compare the success and complication rates of patients with glaucoma who had an Ex-PRESS mini glaucoma shunt device implantation (Optonol, Ltd., Neve Ilan, Israel) to those who had conventional trabeculectomy. PATIENTS AND METHODS The records of 76 eyes of 69 consecutive subjects who had Ex-PRESS implants and 77 eyes of 65 consecutive controls who had trabeculectom...

متن کامل

Combined procedure of phacoemulsification and implantation of Ex-PRESS miniature glaucoma shunt.

Glaucoma patients not responding to maximum medical therapy with coexistent cataract are candidates for combined cataract and glaucoma therapy. There are different therapy models. The choice of therapy depends on numerous patient and surgeon related factors. Ex-PRESS mini glaucoma shunt is a modified trabeculectomy and can be combined with cataract surgery when indicated. In this paper we prese...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of glaucoma

دوره 19 8  شماره 

صفحات  -

تاریخ انتشار 2010