Compact thermal neutron sensors for moderator-based neutron spectrometers.

نویسندگان

  • A Pola
  • D Bortot
  • M V Introini
  • R Bedogni
  • A Gentile
  • A Esposito
  • J M Gómez-Ros
  • E Passoth
  • A Prokofiev
چکیده

In the framework of the NESCOFI@BTF project of the Italian Institute of Nuclear Physics, different types of active thermal neutron sensors were studied by coupling semiconductor devices with a suitable radiator. The objective was to develop a detector of small dimensions with a proper sensitivity to use at different positions in a novel moderating assembly for neutron spectrometry. This work discusses the experimental activity carried out in the framework of the ERINDA program (PAC 3/9 2012) to characterise the performance of a thermal neutron pulse detector based on (6)Li.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimised BNCT facility based on a compact D-D neutron generator

Background: Boron Neutron Capture Therapy (BNCT) is a very promising treatment for patients suffering gliobastoma multiforme, an aggressive type of brain cancer, where conventional radiation therapies fail. Thermal neutrons are suitable for the direct treatment of cancers which are located at near-tissue-surface deep-seated tumors need harder, epithermal neutron energy spectra. Materials and Me...

متن کامل

شبیه‌سازی مونت کارلو یک دستگاه پرتودهی نوترونی به منظور تعیین بازده آشکارسازهای نوترون‌های حرارتی

In this work, a neutron irradiating system containing six Am/Be neutron sources in a graphite moderator, which produces a relatively high and uniform thermal neutron flux in an irradiating cavity at the center of the system , has been  simulated .The thermal neutron flux in the center of the system has then been calculated and compared with experimental results  measured in a cavity a...

متن کامل

The safety of a landmine detection system using graphite and polyethylene moderator

Background: Several landmine detection methods, based on nuclear techniques, have been suggested up to now. Neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are the nuclear methods used for landmine detection. In this paper an optimized (safe and effective) moderating structure using an 241Am-Be neutron source for detecting landmines has been invest...

متن کامل

Investigation of metal hydrides applicability as neutron moderator and shielding by MCNPX

In this research, the applicability of several metal hydrides as neutron moderator and shielding for D-D fusion sources has been investigated by MCNPX code. The results have been investigated in three steps to find the materials with lower thermal, fast and total neutron fluxes than conventional shielding materials. The results show relative advantages of LaNi5H6, VH, TiH2, TaH, Mg (BH4)2, YH2,...

متن کامل

Parameters of the NERA spectrometer for cold and thermal moderators of the IBR-2 pulsed reactor

The inverted geometry time-of-flight spectrometer NERA designed for simultaneous investigation of elastic and inelastic neutron scattering was constructed on a 100 meter long flight path of the IBR-2 reactor at JINR, Dubna, Russia. Spectrometer parameters were optimized for the thermal neutron spectrum of a water moderator at 330 K. Recently, a new type of cold neutron source operating at 30 K ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 161 1-4  شماره 

صفحات  -

تاریخ انتشار 2014