Step-tracking movements of the wrist. IV. Muscle activity associated with movements in different directions.

نویسندگان

  • D S Hoffman
  • P L Strick
چکیده

We examined the patterns of muscle activity associated with multiple directions of step-tracking movements of the wrist in humans and monkeys. Human subjects made wrist movements to 12 different targets that required varying amounts of flexion-extension and radial-ulnar deviation. Wrist muscles displayed two patterns of electromyographic (EMG) modulation as movement direction changed: amplitude graded and temporally shifted. The amplitude-graded pattern was characterized by modulation of the quantity of muscle activity that occurred during two distinct time periods, an agonist burst interval that began before movement onset and an antagonist burst interval that began just after movement onset. The timing of muscle activity over the two intervals showed little variation with changes in movement direction. For some directions of movement, EMG activity was present over both time intervals, resulting in "double bursts." Modulation of activity during the agonist burst interval was particularly systematic and was well fit by a cosine function. In contrast, the temporally shifted pattern was characterized by a gradual change in the timing of a single burst of muscle activity. The burst occurred at a time intermediate between the agonist and antagonist burst intervals. The temporally shifted pattern was seen less frequently than the amplitude-graded pattern and was present only in selected wrist muscles for specific directions of movement. Monkeys made wrist movements to 8-16 different targets that required varying amounts of flexion-extension and radial-ulnar deviation. These movements were performed more slowly than those of human subjects. The wrist muscles of the monkeys we examined displayed the amplitude-graded pattern of activity but not the temporally shifted pattern. Stimulation of individual wrist muscles in monkeys resulted in wrist movements that were markedly curved, particularly for the wrist extensors. These results indicate that step-tracking movements of the wrist are generated mainly by using the amplitude-graded pattern to modulate muscle activity. We propose that this pattern reflects a central process that decomposes an intended movement into an agonist, "propulsive" component and an antagonist, "braking" component. Separate bursts of muscle activity then are generated to control each component. On the other hand, we argue that the temporally shifted pattern may function to reduce the amount of movement curvature associated with the activation of wrist muscles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal control of redundant muscles in step-tracking wrist movements.

An important question in motor neuroscience is how the nervous system controls the spatiotemporal activation patterns of redundant muscles in generating accurate movements. The redundant muscles may not only underlie the flexibility of our movements but also pose the challenging problem of how to select a specific sequence of muscle activation from the huge number of possible activations. Here,...

متن کامل

Deficits in movements of the wrist ipsilateral to a stroke in hemiparetic subjects.

We examined step-tracking movements of the wrist and associated EMG activity in seven patients (age range, 27-73 yr) and in seven normal subjects that were matched to patients in age, sex, and handedness. All patients exhibited a hemiparesis that resulted from a unilateral cerebrovascular accident (CVA) that included motor areas in the frontal lobe or their efferents. The lesion in three patien...

متن کامل

بررسی زمان‌بندی و سطح فعالیت الکتریکی عضلات اطراف مفصل زانو در الگوهای حرکتی فعال و واکنشی در مردان سالم

New studies in neuromuscular control have indicated that the strength of muscle contraction isn’t the only important factor in a task. But the speed at which a muscle responds, preparation of muscle and synergistic pattern at which a group of muscles recruit to a task or respond to a condition are much more important in constant joint stabilization and potential injury prevention. The purpo...

متن کامل

Generating the Visual Biofeedback Signals Applicable to Reduction of Wrist Spasticity: A Pilot Study on Stroke Patients

Introduction: Application of biofeedback techniques in rehabilitation has turned into an exciting research area during the recent decade. Providing an appropriate visual or auditory biofeedback signal is the most critical requirement of a biofeedback technique. In this regard, changes in Surface Electromyography (SEMG) signals during wrist movement can be used to generate an indictable visual b...

متن کامل

Step-tracking Movements of the Wrist. Load on Patterns of Muscle Activity III. Influence Changes

Human subjects performed step-tracking movements of the wrist in the radial direction. Movement amplitude, external load, and accuracy instructions were varied. We used surface electrodes to record muscle activity from an agonist, extensor carpi radialis longus, and an antagonist, extensor carpi ulnaris. When subjects performed movements “as fast as possible” that were opposed by different exte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 81 1  شماره 

صفحات  -

تاریخ انتشار 1999