Limit of blank, limit of detection and limit of quantitation.
نویسندگان
چکیده
* Limit of Blank (LoB), Limit of Detection (LoD), and Limit of Quantitation (LoQ) are terms used to describe the smallest concentration of a measurand that can be reliably measured by an analytical procedure. * LoB is the highest apparent analyte concentration expected to be found when replicates of a blank sample containing no analyte are tested. LoB = mean(blank) + 1.645(SD(blank)). * LoD is the lowest analyte concentration likely to be reliably distinguished from the LoB and at which detection is feasible. LoD is determined by utilising both the measured LoB and test replicates of a sample known to contain a low concentration of analyte. * LoD = LoB + 1.645(SD (low concentration sample)). * LoQ is the lowest concentration at which the analyte can not only be reliably detected but at which some predefined goals for bias and imprecision are met. The LoQ may be equivalent to the LoD or it could be at a much higher concentration.
منابع مشابه
Determination of Astaxanthin in Trout by High Performance Liquid Chromatography Coupled with Visible Detection
Background: Astaxanthin is widely and naturally distributed in marine animals including, crustaceans, such as shrimp, crabs, and fish, such as salmon and trout. Methods: A total of 20 trout samples were collected from local market and were analyzed for astaxanthin via HPLC-UV. Analyte extraction was done by water, methanol, dichloromethane, and acetonitrile 4.5:85:5:45.5, v/v/v/v. Results: Desp...
متن کاملA Novel Approach for Formability Prediction of Tailor Welded Blank
Formability of Tailor Welded Blank (TWB) is an important parameter which limits this kind of blanks usage. A forming criterion for tailor welded blank is presented based on the analytical model in this research. This criterion suggests Limit Strength Ratio (LSR) and Limit Thickness Ratio (LTR) for forming limit of TWB. When thickness ratio or strength ratio in tailor welded blank is greater tha...
متن کاملAnalysis of deep drawing process to predict the forming severity considering inverse finite element and extended strain-based forming limit diagram
An enhanced unfolding Inverse Finite Element Method (IFEM) has been used together with an extended strain-based forming limit diagram (EFLD) to develop a fast and reliable approach to predict the feasibility of the deep drawing process of a part and determining where the failure or defects can occur. In the developed unfolding IFEM, the meshed part is properly fold out on the flat sheet and tre...
متن کاملHigh-Performance Liquid Chromatography Determination of Methotrexate in Plasma
This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...
متن کاملHigh-Performance Liquid Chromatography Determination of Methotrexate in Plasma
This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Clinical biochemist. Reviews
دوره 29 Suppl 1 شماره
صفحات -
تاریخ انتشار 2008