Efficacy of Bone Source™ and Cementek™ in comparison with Endobon™ in critical size metaphyseal defects, using a minipig model.

نویسندگان

  • Christian K G Spies
  • Stefan Schnürer
  • Tobias Gotterbarm
  • Steffen J Breusch
چکیده

INTRODUCTION To examine and compare biocompatibility, osteocompatibility, rate of resorption, and remodelling dynamics of 2 calcium phosphate cements in comparison with a well-established hydroxyapatite ceramic. MATERIALS AND METHODS In a randomised fashion, Bone Source™, Cementek™, and Endobon™ were implanted bilaterally into the proximal metaphyseal tibiae of 35 Göttinger minipigs in a direct right vs. left intra-individual comparison. Fluorescent labelling was used. Histological and morphometric evaluations were carried out at 6, 12, and 52 weeks. RESULTS All bone substitutes showed good biocompatibility, bioactivity, and osteoconductivity. Endobon™ was not degraded over the follow-up period. Cementek™ was degraded constantly and significantly over the time intervals, whereas Bone Source™ was degraded mainly from the 6 week to 12 week interval. After 52 weeks, a significant difference of residual material within the defect zone was detected between all substitutes, with the highest resorption rate for Cementek™. Bone Source™ was least degraded. Defects filled with Endobon™ were characterised by a significantly continuous bony ingrowth over the time intervals. Bone formation within the defects filled with Cementek™ and Bone Source™ showed significant peaks 12 weeks after implantation. After 52 weeks, a significant difference in the amount of new bone within the defect area was detected, with the highest levels for Endobon™, followed by Cementek™. CONCLUSION After 1 year a restitution ad integrum could not be observed in any treatment group. The ceramic Endobon™ showed the expected response histologically. Based on its porosity it excelled in osteoconductivity. Concerning the calcium phosphate cements, a thorough osseous incorporation seemed to inhibit further degradation of both bone substitute materials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification the Effect of Ageing on Characteristics of the Photoplethysmogram Using an Optimized Windkessel Model

Background: With increasing age, some changes appeared in specifications of vessels which including dimensions and elasticity in their. The changes in parameters such as resistance, inertance and compliance vessels appear and eventually changes in the environmental pulse releases are in circulation. These changes clearly appear in specification of photoplethysmogram particularly in the size and...

متن کامل

Thyroid Ultrasonography in Differentiation between Graves’ Disease and Hashimoto’s Thyroiditis

Objective: Graves’ disease and Hashimoto’s thyroiditis are the most common causes of hyper and hypothyroidism, respectively. Differentiation of these 2 diseases, if the patient is euthyroid, may sometimes be extremely difficult on the basis of clinical and laboratory findings. The purpose of this study was to determine the sensitivity and specificity of gray scale sonography in differentiat...

متن کامل

Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach

Introduction: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian L...

متن کامل

Physicochemical Characterization of Altebrel™, a Proposed Etanercept Biosimilar

Background: Etanercept is prescribed for the rapid and effective treatment of chronic immune-mediated inflammatory disorders. Due to the expiration of etanercept patents and worldwide demand for comparable and more affordable substitutes, several biosimilars of etanercept have been approved in different countries and new ones are in the process of approval.Objectives: In the present study...

متن کامل

A Mathematical Approach for Describing Time-Dependent Poisson’s Ratios of Periodontal Ligaments

Periodontal ligament is a thin layer of soft tissue that connects root of a tooth to the surrounding alveolar bone. These ligaments play an important role in initiating tooth movement when loads are applied to teeth with orthodontic appliances. The majority of such soft tissues exhibit as viscoelastic bodies or have a time-dependent behavior. Due to the viscoelastic behavior of the periodontal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied biomaterials & biomechanics : JABB

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2010