Ten Years of Development of Equipment for Measurement of Atmospheric Radioactive Xenon for the Verification of the CTBT

نویسندگان

  • MATTHIAS AUER
  • TIMO KUMBERG
  • HARTMUT SARTORIUS
  • BERND WERNSPERGER
  • CLEMENS SCHLOSSER
چکیده

Atmospheric measurement of radioactive xenon isotopes (radioxenon) plays a key role in remote monitoring of nuclear explosions, since it has a high capability to capture radioactive debris for a wide range of explosion scenarios. It is therefore a powerful tool in providing evidence for nuclear testing, and is one of the key components of the verification regime of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The reliability of this method is largely based on a well-developed measurement technology. In the 1990s, with the prospect of the build-up of a monitoring network for the CTBT, new development of radioxenon equipment started. This article summarizes the physical and technical principles upon which the radioxenon technology is based and the advances the technology has undergone during the last 10 years. In contrast to previously used equipment, which was manually operated, the new generation of radioxenon monitoring equipment is designed for automated and continuous operation in remote field locations. Also the analytical capabilities of the equipment were strongly enhanced. Minimum detectable concentrations of the recently developed systems are well below 1 mBq/ m for the key nuclide Xe for sampling periods between 8 and 24 h. All the systems described here are also able to separately measure with low detection limits the radioxenon isotopes Xe, Xe and Xe, which are also relevant for the detection of nuclear tests. The equipment has been extensively tested during recent years by operation in a laboratory environment and in field locations, by performing comparison measurements with laboratory type equipment and by parallel operation. These tests demonstrate that the equipment has reached a sufficiently high technical standard for deployment in the global CTBT verification regime.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative concept for a major breakthrough in atmospheric radioactive xenon detection for nuclear explosion monitoring

The verification regime of the comprehensive test ban treaty (CTBT) is based on a network of three different waveform technologies together with global monitoring of aerosols and noble gas in order to detect, locate and identify a nuclear weapon explosion down to 1 kt TNT equivalent. In case of a low intensity underground or underwater nuclear explosion, it appears that only radioactive gases, ...

متن کامل

Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms

Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...

متن کامل

Development of RadRob15, A Robot for Detecting Radioactive Contamination in Nuclear Medicine Departments

Accidental or intentional release of radioactive materials into the living or working environment may cause radioactive contamination. In nuclear medicine departments, radioactive contamination is usually due to radionuclides which emit high energy gamma photons and particles. These radionuclides have a broad range of energies and penetration capabilities. Rapid detection of radioactive contami...

متن کامل

Verification of a Quality Management Theory: Using a Delphi Study

Background A model of quality management called Strategic Collaborative Quality Management (SCQM) model was developed based on the quality management literature review, the findings of a survey on quality management assessment in healthcare organisations, semi-structured interviews with healthcare stakeholders, and a Delphi study on healthcare quality management experts. The purpose of this stu...

متن کامل

Historical review of interstitial prostate brachytherapy

In the recent years, interstitial brachytherapy implantation has become the treatment of choice for early stage prostate cancer patients. Treatment of prostate cancer with radiation is traced back to 1909. Originally this treatment modality was very crude and could not gain much popularity till 1982. Advancements in radioactive source designs, introduction of new low energy radioactive sources,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010