Comparison of SPECT/CT, SPECT, and planar imaging with single- and dual-phase (99m)Tc-sestamibi parathyroid scintigraphy.

نویسندگان

  • William C Lavely
  • Sibyll Goetze
  • Kent P Friedman
  • Jeffrey P Leal
  • Zhe Zhang
  • Elizabeth Garret-Mayer
  • Alan P Dackiw
  • Ralph P Tufano
  • Martha A Zeiger
  • Harvey A Ziessman
چکیده

UNLABELLED Various methodologies for (99m)Tc-sestamibi parathyroid scintigraphy are in clinical use. There are few direct comparisons between the different methods and even less evidence supporting the superiority of one over another. Some reports suggest that SPECT is superior to planar imaging. The addition of CT to SPECT may further improve parathyroid adenoma localization. The purpose of our investigation was to compare hybrid SPECT/CT, SPECT, and planar imaging and to determine whether dual-phase imaging is advantageous for the 3 methodologies. METHODS Scintigraphy was performed on 110 patients with primary hyperparathyroidism and no prior neck surgery. Of these, 98 had single adenomas and are the subject of this review. Planar imaging and SPECT/CT were performed at 15 min and 2 h after injection. Six image sets (early and delayed planar imaging, SPECT, and SPECT/CT) and combinations of the 2 image sets were reviewed for adenoma localization at 13 possible sites. Each review was scored for location and certainty of focus by 2 reviewer groups. Surgical location served as the standard. Sensitivity, specificity, area under the curve, positive predictive value, negative predictive value, and kappa-values were determined for each method. RESULTS The overall kappa-coefficient (certainty of adenoma focus) between reading groups was 0.68 (95% confidence interval, 0.66-0.70). The highest values were for dual-phase studies that included SPECT/CT. Dual-phase planar imaging, SPECT, and SPECT/CT were statistically significantly superior to single-phase early or delayed imaging in sensitivity, area under the curve, and positive predictive value. Neither single-phase nor dual-phase SPECT was statistically superior to dual-phase planar imaging. Early-phase SPECT/CT in combination with any delayed imaging method was superior to dual-phase planar imaging or SPECT for sensitivity, area under the curve, and positive predictive value. CONCLUSION Early SPECT/CT in combination with any delayed imaging method was statistically significantly superior to any single- or dual-phase planar or SPECT study for parathyroid adenoma localization. Localization with dual-phase acquisition was more accurate than with single-phase (99m)Tc-sestamibi scintigraphy for planar imaging, SPECT, and SPECT/CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SPECT-CT fusion in the diagnosis of hyperparathyroidism

Objective(s): In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Methods: Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) we...

متن کامل

Value of dual-phase (99m)Tc-sestamibi scintigraphy with neck and thoracic SPECT/CT in secondary hyperparathyroidism.

OBJECTIVE Surgical intervention in the form of parathyroidectomy is generally considered only for severe secondary hyperparathyroidism (sHPT). However, correct location of the parathyroid glands before parathyroidectomy is a challenge. The purpose of this study was to compare the diagnostic value of early and delayed phase (99m)Tc-sestamibi SPECT/CT in the detection of parathyroid tissue to gui...

متن کامل

Comparison of Five Parathyroid Scintigraphic Protocols

Objectives. We compared five parathyroid scintigraphy protocols in patients with primary (pHPT) and secondary hyperparathyroidism (sHPT) and studied the interobserver agreement. The dual-tracer method ((99m)Tc-sestamibi/(123)I) was used with three acquisition techniques (parallel-hole planar, pinhole planar, and SPECT/CT). The single-tracer method ((99m)Tc-sestamibi) was used with two acquisiti...

متن کامل

Absent radiotracer uptake in thyroid gland in parathyroid scintigraphy with 99mTc-MIBI: A case report

Localization of 99mTc- hexakis-2-methoxyisobutylisonitrile (99mTc-MIBI) by parathyroid adenomas is well known, and this warrants MIBI scan to evaluate suspected parathyroid adenoma in primary hyperparathyroidism. Typically, the radionuclide concentrates in both the thyroid gland and parathyroid adenoma in early images, and later on delayed images washes out slowly from the...

متن کامل

Parathyroid scintigraphy in patients with primary hyperparathyroidism: 99mTc sestamibi SPECT and SPECT/CT.

The clinical diagnosis of primary hyperparathyroidism is based largely on serum laboratory test results, as patients often are asymptomatic. Surgery, often with bilateral exploration of the neck, has been considered the definitive treatment for symptomatic disease. However, given that approximately 90% of cases are due to a single parathyroid adenoma, a better treatment may be the selective sur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 48 7  شماره 

صفحات  -

تاریخ انتشار 2007