The effect of adding tobramycin to Simplex P cement on femoral stem micromotion as measured by radiostereometric analysis

نویسندگان

  • Eric Bohm
  • Martin Petrak
  • Trevor Gascoyne
  • Thomas Turgeon
چکیده

BACKGROUND Previous in vitro research on addition of antibiotics to bone cement has found no statistically significant deterioration in mechanical properties. However, no clinical studies have compared the performance of tobramycin-laden bone cement with that of standard bone cement (Simplex P). PATIENTS AND METHODS 23 patients (25 hips) were randomized to receive an Exeter (Stryker Orthopaedics) femoral stem cemented with either Simplex P (standard) or Simplex T (tobramycin-laden) cement. There were 2 years of follow-up, with scheduled radiostereometric (RSA) examinations. RESULTS All stems migrated distally and showed some degree of retroversion. No clinically significant differences in stem subsidence or retroversion were found between the Simplex T and Simplex P cement groups after 2 years. Overall subsidence was less than in previous studies, probably due to a postponed initial post-surgical examination. Rates of subsidence in both cement groups were consistent with those from previous studies of Exeter stems. INTERPRETATION Subsidence of the femoral stem after 2 years was similar in the Simplex T (tobramycin-laden) and Simplex P (standard) groups.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors associated with excessive migration in bone impaction hip revision surgery: a radiostereometric analysis study.

A prospective radiostereometric analysis (RSA) study of 18 patients with cemented revision hip surgery and impaction grafting with an Exeter stem was done with a follow-up of 2 years for all patients. All factors that could influence migration (ie, micromotion) of the stem were analyzed with a repeated measurements analysis of variance. Two groups could be identified: a stable group and a conti...

متن کامل

Wear of a sequentially annealed polyethylene acetabular liner

BACKGROUND AND PURPOSE We previously reported on a randomized controlled trial (RCT) that examined the effect of adding tobramycin to bone cement after femoral stem migration. The present study examined femoral head penetration into both conventional and highly crosslinked polyethylene acetabular liners in the same group of RCT patients, with a minimum of 5 years of postoperative follow-up. P...

متن کامل

A Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?

Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...

متن کامل

Ten-year RSA-measured migration of the Exeter femoral stem.

The Exeter femoral stem is a double-tapered highly polished collarless cemented implant with good long-term clinical results. In order to determine why the stem functions well we have undertaken a long-term radiostereometric analysis (RSA) study. A total of 20 patients undergoing primary Exeter total hip replacement for osteoarthritis using the Hardinge approach were recruited and followed with...

متن کامل

A study of the Elite Plus femoral component using radiostereometric analysis.

We performed a three-year radiostereometric analysis (RSA) study of the Elite Plus femoral component on 25 patients undergoing primary total hip replacement. Additional assessments and measurements from standard radiographs were also made. Subsidence of the stem occurred at the cement-stem interface. At 36 months the subsidence of the stem centroid was a mean of 0.30 mm (0.02 to 1.28), and was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 83  شماره 

صفحات  -

تاریخ انتشار 2012