View-synchronized robotic image-guided therapy for atrial fibrillation ablation: experimental validation and clinical feasibility.
نویسندگان
چکیده
BACKGROUND A robotic catheter navigation system has been developed that provides a significant degree of freedom of catheter movement. This study examines the feasibility of synchronizing this robotic navigation system with electroanatomic mapping and 3-dimensional computed tomography imaging to perform view-synchronized left atrial (LA) ablation. METHODS AND RESULTS This study consisted of a porcine experimental validation phase (9 animals) and a clinical feasibility phase (9 atrial fibrillation patients). Preprocedural computed tomography images were reconstructed to provide 3-dimensional surface models of the LA pulmonary veins and aorta. Aortic electroanatomic mapping was performed manually, followed by registration with the corresponding computed tomography aorta image using custom software. The mapping catheter was remotely manipulated with the robotic navigation system within the registered computed tomography image of the LA pulmonary veins. The point-to-surface error between the LA electroanatomic mapping data and the computed tomography image was 2.1+/-0.7 and 1.6+/-0.1 mm in the preclinical and clinical studies, respectively. The catheter was remotely navigated into all pulmonary veins, the LA appendage, and circumferentially along the mitral valve annulus. In 7 of 9 animals, circumferential radiofrequency ablation lesions were applied periostially to ablate 11 pulmonary veins. In patients, all of the pulmonary veins were remotely electrically isolated in an extraostial fashion. Adjunctive ablation included superior vena cava isolation in 6 patients, cavotricuspid isthmus ablation in 5 patients, and ablation of sites of complex fractionated activity and atypical LA flutters in 3 patients. CONCLUSIONS This study demonstrates the safety and feasibility of an emerging paradigm for atrial fibrillation ablation involving the confluence of 3 technologies: 3-dimensional imaging, electroanatomic mapping, and remote robotic navigation.
منابع مشابه
Three-dimensional ultrasound for image-guided mapping and intervention: methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system.
BACKGROUND Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. METHODS AND RESULTS Twelve dogs underwent evaluation using a new...
متن کاملEffect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملEffect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملVisually-guided balloon catheter ablation of atrial fibrillation: experimental feasibility and first-in-human multicenter clinical outcome.
BACKGROUND Electric isolation of the pulmonary veins (PVs) can successfully treat patients with paroxysmal atrial fibrillation. However, it remains technically challenging to identify the left atrial-PV junction and sequentially position the ablation catheter in a point-by-point contiguous fashion to isolate the PVs. In this study, a novel endoscopic ablation system was used to directly visuali...
متن کاملOptimal Transseptal Puncture Location for Robot-Assisted Left Atrial Catheter Ablation
BACKGROUND The preferred method of treatment for atrial fibrillation (AF) is by catheter ablation, in which a catheter is guided into the left atrium through a transseptal puncture. However, the transseptal puncture constrains the catheter, thereby limiting its manoeuvrability and increasing the difficulty in reaching various locations in the left atrium. In this paper, we address the problem o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 115 21 شماره
صفحات -
تاریخ انتشار 2007