Thoracic spinal cord stimulation reduces the risk of ischemic ventricular arrhythmias in a postinfarction heart failure canine model.
نویسندگان
چکیده
BACKGROUND Thoracic spinal cord stimulation (SCS) is a promising therapy in treating refractory angina. This study was designed to investigate SCS with regard to the risk of arrhythmias during myocardial ischemia and its cardiac electrophysiological effects. METHODS AND RESULTS We studied 22 dogs with healed anterior myocardial infarction (MI) and superimposed heart failure (HF) induced by rapid ventricular pacing. SCS was applied at the dorsal T1-T2 segments of the spinal cord (at 50 Hz, 0.2 ms) for 15 minutes. Transient (2-minute) myocardial ischemia was induced on 2 separate occasions (no SCS and SCS) to provoke ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation; VT/VF). Ischemic episodes were separated by 90 minutes, and dogs were randomly assigned to receive SCS or no SCS before the first or second ischemic episode. SCS reduced the occurrence of VT/VF from 59% to 23% when SCS was applied during transient myocardial ischemia (odds ratio, 0.36; 95% confidence interval, 0.1626 to 0.5646; P=0.0009). SCS also decreased sinus rate by 7.5+/-14 bpm (P=0.048), increased the PR interval by 11.1+/-14.7 ms (P=0.009), and reduced systolic blood pressure by 9.8+/-13.6 mm Hg (P=0.02). CONCLUSIONS Thoracic SCS appears to protect against ischemic VT/VF in a canine model of healed MI and HF. SCS reduced sinus rate and systolic blood pressure, changes consistent with the previously known antisympathetic effect of SCS, which may have contributed to the antiarrhythmic benefits.
منابع مشابه
Spinal cord stimulation improves ventricular function and reduces ventricular arrhythmias in a canine postinfarction heart failure model.
BACKGROUND Spinal cord stimulation (SCS) reduces the incidence of ventricular tachyarrhythmias in experimental models. This study investigated the effects of long-term SCS on ventricular function in a postinfarction canine heart failure model. METHODS AND RESULTS In stage 1, dogs underwent implantable cardioverter-defibrillator implantation and embolization of the left anterior descending art...
متن کاملCan chronotropic incompetence predict life-threatening ventricular arrhythmias in patients with stable ischemic heart disease?
Background: Chronotropic incompetence has prognostic value of all-cause and cardiovascular mortality in both patients with asymptomatic and symptomatic ischemic heart disease (IHD), regardless of traditional risk factors. The aim of this study was to investigate the relationship between chronotropic response during exercise test and the development of ventricular arrhythmias. Methods: 153 pati...
متن کاملMyoblast transfer in ischemic heart failure: effects on rhythm stability.
Skeletal myoblast (SM) implantation promotes recovery of myocardial function after ischemic injury. Clinical observations suggest an association of SM implantation and ventricular arrhythmias. Support for this link has been sought in animal studies, but none employing models of congestive heart failure. In a canine model of postinfarction congestive heart failure (CHF) we compared the frequency...
متن کاملPreconditioning effects of oxytocin in reducing cardiac arrhythmias in a rat heart regional ischemia-reperfusion model
Abstract Introduction: Occurrence of cardiac arrhythmias and myocardial infarction are two main deleterious events that are caused by ischemia-reperfusion (IR) injury in the heart. Cardiac preconditioning represents the most potent method of rescuing heart tissue from undergoing irreversible ischemic damage. The aim of the present study was to evaluate oxytocin (OT) cardioprotective effect...
متن کاملEffects of Acetyl-L-Carnitine on Cardiac Arrhythmias and Infarct Size in Ischemic-Reperfused Isolated Rat Heart
Objective(s) This study aimed to examine whether acetyl-L-carnitine (ALC) was able to reduce cardiac arrhythmias and infarct size in the ischemic-reperfused isolated rat heart. Materials and Methods The isolated hearts were mounted on a Langendorff apparatus then perfused by a modified Krebs-Henseleit solution during 30 min regional ischemia and 120 min reperfusion (control) or by enriched K...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 111 24 شماره
صفحات -
تاریخ انتشار 2005