Comparison between 3D volumetric rendering and multiplanar slices on the reliability of linear measurements on CBCT images: an in vitro study

نویسندگان

  • Thais Maria Freire FERNANDES
  • Julie ADAMCZYK
  • Marcelo Lupion POLETI
  • José Fernando Castanha HENRIQUES
  • Bernard FRIEDLAND
  • Daniela Gamba GARIB
چکیده

OBJECTIVE The purpose of this study was to determine the accuracy and reliability of two methods of measurements of linear distances (multiplanar 2D and tridimensional reconstruction 3D) obtained from cone-beam computed tomography (CBCT) with different voxel sizes. MATERIAL AND METHODS Ten dry human mandibles were scanned at voxel sizes of 0.2 and 0.4 mm. Craniometric anatomical landmarks were identified twice by two independent operators on the multiplanar reconstructed and on volume rendering images that were generated by the software Dolphin®. Subsequently, physical measurements were performed using a digital caliper. Analysis of variance (ANOVA), intraclass correlation coefficient (ICC) and Bland-Altman were used for evaluating accuracy and reliability (p<0.05). RESULTS Excellent intraobserver reliability and good to high precision interobserver reliability values were found for linear measurements from CBCT 3D and multiplanar images. Measurements performed on multiplanar reconstructed images were more accurate than measurements in volume rendering compared with the gold standard. No statistically significant difference was found between voxel protocols, independently of the measurement method. CONCLUSIONS Linear measurements on multiplanar images of 0.2 and 0.4 voxel are reliable and accurate when compared with direct caliper measurements. Caution should be taken in the volume rendering measurements, because the measurements were reliable, but not accurate for all variables. An increased voxel resolution did not result in greater accuracy of mandible measurements and would potentially provide increased patient radiation exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative linear accuracy and reliability of cone beam CT derived 2-dimensional and 3-dimensional images constructed using an orthodontic volumetric rendering program

COMPARA TIVE LINEAR ACCURACY AND RELIABILITY OF CONE BEAM CT DERIVED 2-DIMENSIONAL AND 3-DIMENSIONAL IMAGES CONSTRUCTED USING AN ORTHODONTIC VOLUMETRIC RENDERING PROGRAM. Danielle R. Periago, D.M.D. June 12, 2007 The purpose of this project was to compare the accuracy and reliability of linear measurements made on 2D projections and 3D reconstructions using Dolphin 3D software (Chatsworth, CA) ...

متن کامل

Pharyngeal Airway: An Analysis Using 2D vs. 3D Images in Different Malocclusions

Introdouction: The aim of this study was to compare information regarding pharyngeal airway sizes in adolescent subjects with different malocclusion classes obtained from lateral cephalograms and 3–dimensional (3D) cone-beam computed tomography (CBCT) scans. Materials and methods: In this prospective cross-sectional study, CBCT scans and lateral cephalograms of 35 subjects, taken with...

متن کامل

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

Investigation of the effect of slice thickness and Kvp changes on the accuracy of linear measurements in CBCT: In vitro study

Background and Aim: The accuracy of linear measurements in CBCT images is one of the critical parameters in treatment planning. Slice thickness and exposure parameters seem to affect the accuracy of linear measurements. In this study, we investigated the impact of the above factors on the accuracy of linear measurements in CBCT. Materials and Methods: For the in vitro experiment, three dry huma...

متن کامل

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2015