Silver-coated endotracheal tubes and incidence of ventilator-associated pneumonia: the NASCENT randomized trial.

نویسندگان

  • Marin H Kollef
  • Bekele Afessa
  • Antonio Anzueto
  • Christopher Veremakis
  • Kim M Kerr
  • Benjamin D Margolis
  • Donald E Craven
  • Pamela R Roberts
  • Alejandro C Arroliga
  • Rolf D Hubmayr
  • Marcos I Restrepo
  • William R Auger
  • Regina Schinner
چکیده

CONTEXT Ventilator-associated pneumonia (VAP) causes substantial morbidity. A silver-coated endotracheal tube has been designed to reduce VAP incidence by preventing bacterial colonization and biofilm formation. OBJECTIVE To determine whether a silver-coated endotracheal tube would reduce the incidence of microbiologically confirmed VAP. DESIGN, SETTING, AND PARTICIPANTS Prospective, randomized, single-blind, controlled study conducted in 54 centers in North America. A total of 9417 adult patients (> or = 18 years) were screened between 2002 and 2006. A total of 2003 patients expected to require mechanical ventilation for 24 hours or longer were randomized. INTERVENTION Patients were assigned to undergo intubation with 1 of 2 high-volume, low-pressure endotracheal tubes, similar except for a silver coating on the experimental tube. MAIN OUTCOME MEASURES Primary outcome was VAP incidence based on quantitative bronchoalveolar lavage fluid culture with 10(4) colony-forming units/mL or greater in patients intubated for 24 hours or longer. Other outcomes were VAP incidence in all intubated patients, time to VAP onset, length of intubation and duration of intensive care unit and hospital stay, mortality, and adverse events. RESULTS Among patients intubated for 24 hours or longer, rates of microbiologically confirmed VAP were 4.8% (37/766 patients; 95% confidence interval [CI], 3.4%-6.6%) in the group receiving the silver-coated tube and 7.5% (56/743; 95% CI, 5.7%-9.7%) (P = .03) in the group receiving the uncoated tube (all intubated patients, 3.8% [37/968; 95% CI, 2.7%-5.2%] and 5.8% [56/964; 95% CI, 4.4%-7.5%] [P = .04]), with a relative risk reduction of 35.9% (95% CI, 3.6%-69.0%; all intubated patients, 34.2% [95% CI, 1.2%-67.9%]). The silver-coated endotracheal tube was associated with delayed occurrence of VAP (P = .005). No statistically significant between-group differences were observed in durations of intubation, intensive care unit stay, and hospital stay; mortality; and frequency and severity of adverse events. CONCLUSION Patients receiving a silver-coated endotracheal tube had a statistically significant reduction in the incidence of VAP and delayed time to VAP occurrence compared with those receiving a similar, uncoated tube. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00148642.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-effectiveness analysis of a silver-coated endotracheal tube to reduce the incidence of ventilator-associated pneumonia.

OBJECTIVE To conduct a cost-effectiveness analysis of the economic outcomes of ventilator-associated pneumonia (VAP) prevention associated with silver-coated endotracheal tubes versus uncoated endotracheal tubes. DESIGN We used a simple decision model based on a hypothetical 1,000-patient cohort intubated with silver-coated or uncoated endotracheal tubes. The primary end point was marginal ho...

متن کامل

Flu Vaccine Didn ’ t Cut Pneumonia Risk in the Elderly

E tubes coated with silver, which has shown potent broad-spectrum antimicrobial activity in vitro, reduced the incidence of ventilatorassociated pneumonia by 35% in a multicenter study, researchers reported. “This is the first intervention demonstrated to reduce ventilator-associated pneumonia incidence that does not require more effort or supervision from clinicians providing bedside care,” sa...

متن کامل

Endotracheal tube-associated pneumonia.

1. Pneumatikos IA, Dragoumanis CK, Bouros DE: Ventilator-associated pneumonia or endotracheal tube-associated pneumonia? An approach to the pathogenesis and preventive strategies emphasizing the importance of endotracheal tube. ANESTHESIOLOGY 2009; 110:673–80 2. Berra L, Curto F, Li Bassi G, Laquerriere P, Baccarelli A, Kolobow T: Antibacterial-coated tracheal tubes cleaned with the Mucus Shave...

متن کامل

Evaluation of the Effects of Oronasal Versus Oral Disinfections with Chlorhexidine on Clinical Criteria of Ventilator-associated Pneumonia

Background: Ventilator-associated pneumonia (VAP) is the most prevalent and lethal form of nosocomial infections in the ICU and oral disinfection is a nursing measure to prevent this condition. Aim: this study aimed to evaluate the effect of oronasal versus oral disinfections with chlorhexidine on the clinical criteria for diagnosis of VAP. Method: This randomized clinical trial was conducted o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA

دوره 300 7  شماره 

صفحات  -

تاریخ انتشار 2008