Spatial orientation of cross-sectional images of coronary arteries: point of view in intracoronary imaging
نویسندگان
چکیده
BACKGROUND In studies where cross-sectional images of coronary arteries obtained with different imaging modalities are compared, the importance of correct co-localization and matching of images along the coronary artery longitudinal axis is obvious. However, it appears neglected that correct spatial orientation of the cross-sectional plane may not be obtainable just by rotating the images to ensure co-localization of identifiable landmarks such as sidebranches. A cross-section has two sides, one facing proximally and the other distally, and pairs of images reconstructed corresponding to these opposite points of view are mirror images of each other and not superimposable. This may be difficult if not impossible to recognize and unrecognized it will give rise to flawed results in the development and validation of imaging technologies aimed at plaque characterization (tissue mapping). We determined the imagined point of view for three commercially available intracoronary imaging systems used by invasive cardiologists and illustrate its importance in imaging modality validation. METHODS AND RESULTS We made an asymmetric phantom and investigated it with two different intravascular ultrasound (IVUS) systems and one optical coherence tomography (OCT) system. The asymmetry of the phantom allowed determination of the spatial orientation of the cross-sectional images. On all tested systems, an observer should imagine herself/himself standing proximal to the cross-section when looking at the intravascular images. CONCLUSIONS The tested intracoronary imaging modalities displayed cross-sectional images with a spatial orientation corresponding to a proximal point of view. Knowledge of the spatial orientation is mandatory when comparing and validating different imaging modalities aimed at plaque characterization.
منابع مشابه
Point of View Intravascular Ultrasound : A Histological Study of Vessels During Life
uring the last several years, dramatic developD ments have taken place in the area of cardiac imaging techniques. From an era of imaging by silhouettes (chest roentgenography, fluoroscopy, angiocardiography, angiography), we have emerged into an era of imaging by tomographic scanning (echocardiography, radionuclide and computed tomography, magnetic resonance).l-3 Two-dimensional intravascular e...
متن کاملIntracoronary MR imaging using a 0.014-inch MR imaging-guidewire: toward MRI-guided coronary interventions.
PURPOSE To validate the feasibility of using a newly designed MR imaging-guidewire (MRIG) to guide angioplasty balloon placement in coronary arteries. MATERIALS AND METHODS A custom gold/sliver/Nitinol/MP35N-based, 0.014-inch MRIG was manufactured. To test its mechanical performance we used the new MRIG to catheterize the left coronary arteries of three dogs under x-ray fluoroscopy. To furthe...
متن کامل'Gold Standard' for Vascular Imaging
uring the last several years, dramatic developD ments have taken place in the area of cardiac imaging techniques. From an era of imaging by silhouettes (chest roentgenography, fluoroscopy, angiocardiography, angiography), we have emerged into an era of imaging by tomographic scanning (echocardiography, radionuclide and computed tomography, magnetic resonance).l-3 Two-dimensional intravascular e...
متن کاملIntravascular ultrasound imaging of human coronary arteries in vivo. Analysis of tissue characterizations with comparison to in vitro histological specimens.
BACKGROUND Intravascular ultrasound imaging was performed in 27 patients after coronary balloon angioplasty to quantify the lumen and atheroma cross-sectional areas. METHODS AND RESULTS A 20-MHz ultrasound catheter was inserted through a 1.6-mm plastic introducer sheath across the dilated area to obtain real-time images at 30 times/sec. The ultrasound images distinguished the lumen from ather...
متن کاملThree-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging.
OBJECTIVES We present the first clinical experience with intracoronary optical frequency domain imaging (OFDI) in human patients. BACKGROUND Intracoronary optical coherence tomography (OCT) is a catheter-based optical imaging modality that is capable of providing microscopic (approximately 7-microm axial resolution, approximately 30-microm transverse resolution), cross-sectional images of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2012