A noncompliant, high pressure balloon to manage undilatable coronary lesions.

نویسندگان

  • Yogesh Raja
  • Helen C Routledge
  • Sagar N Doshi
چکیده

Undilatable coronary lesions, due to coronary calcification, are encountered with increasing frequency. Percutaneous intervention of such lesions comes with the risk of stent underexpansion, which increases the risk of stent thrombosis and restenosis. A variety of techniques and devices are available to assist the interventionist in the treatment of calcified lesions. The OPN NC (SIS-Medical AG, Winterthur, Switzerland) is a high-pressure balloon (rated burst pressure 35 atm) that uses a novel, twin-layer balloon technology to ensure uniform balloon expansion, eliminating "dog-boning." We report four cases of successful treatment of calcified lesions with the OPN NC balloon after dilatation with standard noncompliant balloons to high-pressure failed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rotational ablation assisted angioplasty of an obstructed aortopulmonary collateral artery.

A 15 month old baby girl with pulmonary atresia, ventricular septal defect, and multiple aortopulmonary collateral arteries underwent rotational ablation assisted balloon angioplasty of a severely stenosed collateral artery that had previously proved undilatable using a high pressure non-compliant balloon angioplasty catheter. It is postulated that the rotablation debulked a fibrotic stricture ...

متن کامل

CASE REPORT Rotational ablation assisted angioplasty of an obstructed aortopulmonary collateral artery

A 15 month old baby girl with pulmonary atresia, ventricular septal defect, and multiple aortopulmonary collateral arteries underwent rotational ablation assisted balloon angioplasty of a severely stenosed collateral artery that had previously proved undilatable using a high pressure non-compliant balloon angioplasty catheter. It is postulated that the rotablation debulked a fibrotic stricture ...

متن کامل

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Adjunctive Strategies in the Management of Resistant, ‘Undilatable’ Coronary Lesions After Successfully Crossing a CTO with a Guidewire

Successful revascularisation of chronic total occlusions (CTOs) remains one of the greatest challenges in the era of contemporary percutaneous coronary intervention (PCI). Such lesions are encountered with increasing frequency in current clinical practice. A predictable increase in the future burden of CTO management can be anticipated given the ageing population, increased rates of renal failu...

متن کامل

Very high-pressure dilatation for undilatable coronary lesions: indications and results with a new dedicated balloon.

AIMS Calcific coronary lesions impose a rigid obstacle to optimal balloon and stent expansion and the 20 to 30 atm limit that non-compliant (NC) balloons reach can be insufficient. The aim of our study was to evaluate the safety and efficacy of a new dedicated super high-pressure NC balloon (OPN NC®; SIS Medical AG, Winterthur, Switzerland). METHODS AND RESULTS We retrospectively evaluated a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

دوره 75 7  شماره 

صفحات  -

تاریخ انتشار 2010