Electrochemical Sensors for Detection of Acetylsalicylic Acid

نویسندگان

  • Veronika Supalkova
  • Jiri Petrek
  • Ladislav Havel
  • Sona Krizkova
  • Jitka Petrlova
  • Vojtech Adam
  • David Potesil
  • Petr Babula
  • Miroslava Beklova
  • Ales Horna
  • Rene Kizek
چکیده

Acetylsalicylic acid (AcSA), or aspirin, was introduced in the late 1890s and has been used to treat a variety of inflammatory conditions. The aim of this work was to suggest electrochemical sensor for acetylsalicylic detection. Primarily, we utilized square wave voltammetry (SWV) using both carbon paste electrode (CPE) and of graphite pencil electrode (GPE) as working ones to indirect determination of AcSA. The principle of indirect determination of AcSA bases in its hydrolysis on salicylic acid (SA), which is consequently detected. Thus, we optimized both determination of SA and conditions for AcSA hydrolysis and found out that the most suitable frequency, amplitude, step potential and the composition and pH of the supporting electrolyte for the determination of SA was 260 Hz, 50 mV, 10 mV and Britton-Robinson buffer (pH 1.81), respectively. The detection limit (S/N = 3) of the SA was 1.3 ng/ml. After that, we aimed on indirect determination of AcSA by SWV CPE. We tested the influence of pH of Britton-Robinson buffer and temperature on yield of hydrolysis, and found out that 100% hydrolysis of AcSA was reached after 80 minutes at pH 1.81 and 90°C. The method for indirect determination of AcSA has been utilized to analyse pharmaceutical drug. The determined amount of AcSA in Sensors 2006, 6 1484 the pharmaceutical drug was in good agreement with the declared amounts. Moreover, we used GPE for determination of AcSA in a pharmaceutical drug. Base of the results obtained from stationary electrochemical instrument we used flow injection analysis with electrochemical detection to determine of salicylates (SA, AcSA, thiosalicylic acid, 3,5dinitrosalicylic acid and 5-sulfosalicylic acid – SuSA). We found out that we are able to determine all of detected salicylates directly without any pre-treatment, hydrolysis and so on at units of femtomoles per injection (5 μl).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Label-free electrochemical biosensors for food and drug application

In food sector, there is a huge demand for rapid, reliable, user & eco-friendly biosensors to analyse the quality and safety of food products. Biosensor based methodology depends upon the recognition of a specific antigens or receptors by corresponding antibodies, aptamers or high-affinity ligands. The first scientifically commercialised sensors were the electrochemical sensors used for the ana...

متن کامل

Label-free electrochemical biosensors for food and drug application

In food sector, there is a huge demand for rapid, reliable, user & eco-friendly biosensors to analyse the quality and safety of food products. Biosensor based methodology depends upon the recognition of a specific antigens or receptors by corresponding antibodies, aptamers or high-affinity ligands. The first scientifically commercialised sensors were the electrochemical sensors used for the ana...

متن کامل

Facile Synthesis and Electrochemical Performance of Graphene-Modified Cu2O Nanocomposite for Use in Enzyme-Free Glucose Biosensor

Graphene-modified Cu2O nanocomposite was synthesized under facile microwave irradiation of an aqueous solution and has been investigated as an enzyme-free glucose biosensor. Morphology and crystal structure of the graphene-modified Cu2O nanocomposite were investigated by using electron microscopy and X-Ray Diffraction (XRD) analyses. Also, the electrochemical performan...

متن کامل

An Overview of Prophylactic Acetylsalicylic Acid for the Prevention of Intra-uterine Growth Restriction (IUGR) in Women at Risk for Preeclampsia

Background: Preeclampsia is a major global cause of maternal, neonatal and perinatal mortality. The aim of this review was to summarize all reviews on Acetylsalicylic Acid for the prevention of Intra-uterine Growth Restriction (IUGR) in women at risk for Preeclampsia. Materials and Methods: In this overview we searched databases followin...

متن کامل

Application of Graphene and Graphene Oxide for modification of electrochemical sensors and biosensors: A review

This paper gives a comprehensive review about the most recent progress in graphene and graphene oxide based electrochemical sensors and biosensors.  Graphene, emerging as a true 2-dimensional material, has received increasing attention due to its unique physicochemical properties (high surface area, excellent conductivity, high mechanical strength, and ease of functionalization and mass product...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006