Mobility assessment with the Periotest system in relation to histologic findings of oral implants.
نویسنده
چکیده
The relationship between mobility assessment with the Periotest system and histologic findings was evaluated for oral implants. Five screw-type implants of pure titanium were placed in the mandibles of four monkeys. Two implants in each monkey were occlusally overloaded. These implants were brushed once a week. Plaque was allowed to accumulate around unloaded implants with abutments in the same monkeys. During the experiment, six of eight implants with occlusal overload showed increased manually detectable mobility. Two of these were lost. After 18 months of experimentation, the mobility was assessed using the Periotest system. Sections of the implants and surrounding tissue were cut. For the excessive occlusally loaded implants with manually detectable mobility, positive Periotest values were recorded, and for all other implants the values were negative (range = -7 to -2). All implants with plaque accumulation were histologically osseointegrated but showed marginal bone loss. Two of the implants with occlusal overload had lost osseointegration completely, and two other implants were osseointegrated in the apical part only. A statistically significant association between the Periotest values and the histologic bone level or the proportion of bone-implant contact was observed. If only clinically stable implants (i.e., without manually detectable mobility or with a negative Periotest value) were included in the analysis, no significant correlation was found. The Periotest values revealed only slightly more information concerning the osseointegration of implants than manual mobility assessments.
منابع مشابه
Evaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study
Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...
متن کاملThe relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: an experimental animal study.
The objective of this study was to analyze the efficacy and correlation between clinical and histologic parameters used to evaluate oral implants. After extraction of the premolars and a healing time of 4 months in 16 Dutch goats, four Brånemark implants were placed in the maxillary left and right premolar regions. After a healing time of 6 months, followed by another 4 months with the permucos...
متن کاملA prospective study to assess osseointegration of dental endosseous implants with the Periotest instrument.
Long-term studies have documented the successful treatment of edentulous and partially edentulous patients with titanium implants. However, the inability to identify some non-osseointegrated implants before occlusal loading is costly to practitioners and patients. This study followed all patients (n = 40) who had implants placed over a 6-month period. The Periotest instrument was used at Stage ...
متن کاملMeasuring abutment/implant joint integrity with the Periotest instrument.
Maintenance of the integrity of the abutment/implant interface is essential and is dependent on the abutment screw retaining a preload. Evaluation of this joint is usually done by manual assessment. The purpose of the current study was to determine whether the Periotest instrument could be used to evaluate abutment screw loosening. A custom-designed apparatus was constructed to measure abutment...
متن کاملA healing period increases mini-implant stability in growing rats.
We assessed the stability of orthodontic mini-implants in young rats. Male rats with mean ages of 6 weeks (n = 16) and 20 weeks (n = 16) were divided into four groups (n = 8 each). In the 6- and 20-week immediate-loading groups, immediately after placement, mini-implants were exposed to an experimental traction force for 2 weeks. In the 6- and 20-week healing groups, the force was applied for 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 13 3 شماره
صفحات -
تاریخ انتشار 1998