Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position
نویسندگان
چکیده
BACKGROUND It remains to be elucidated whether the Trendelenburg position increases intracranial pressure (ICP). ICP can be evaluated by measuring the sonographic optic nerve sheath diameter (ONSD). We investigated the effect of the isolated Trendelenburg position on ONSD in patients undergoing robot-assisted laparoscopic radical prostatectomy. Additionally, we evaluated the effect of the Trendelenburg position combined with pneumoperitoneum on ONSD. METHODS Twenty-one patients scheduled for robot-assisted laparoscopic radical prostatectomy were enrolled. Sonographic ONSDs and hemodynamic parameters were measured at specific time points: in the supine position after induction of anesthesia, 3 min after the steep Trendelenburg position (35° incline), 3 min after the steep Trendelenburg position combined with pneumoperitoneum, and in the supine position after desufflation of the pneumoperitoneum. RESULTS The ONSD 3 min after the steep Trendelenburg position was significantly higher than that of the supine position after induction of anesthesia (5.1 ± 0.3 mm vs. 4.5 ± 0.4 mm). In addition, the ONSD 3 min after the steep Trendelenburg position combined with pneumoperitoneum was higher than that of the supine position after induction of anesthesia (4.9 ± 0.4 mm vs. 4.5 ± 0.4 mm). The ONSD in the supine position after desufflation of the pneumoperitoneum was similar to that in the supine position after induction of anesthesia. CONCLUSIONS Use of the isolated steep Trendelenburg position, for even a short duration, increased the sonographic ONSD, providing a better understanding of the effect of only a transient steep Trendelenburg position on ONSD as a surrogate measure for ICP.
منابع مشابه
Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
BACKGROUND Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during pneumoperitoneum combined with the Trendelen...
متن کاملAuthor's response to reviews Title:Sonographic Optic Nerve Sheath Diameter as a Surrogate Measure for Intracranial Pressure in Anesthetized Patients in the Trendelenburg Position Authors:
متن کامل
Effect of scuba-diving on optic nerve and sheath diameters
Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated. Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...
متن کاملBedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children.
STUDY OBJECTIVE We investigate the test performance of emergency physician-performed sonographic measurement of optic nerve sheath diameter for diagnosis of increased intracranial pressure. METHODS Children between the ages of 0 and 18 years with suspected increased intracranial pressure were prospectively recruited from the emergency department and ICU of an urban, tertiary-level, freestandi...
متن کاملPosition does not affect the optic nerve sheath diameter during laparoscopy
BACKGROUND Increase in intracranial pressure (ICP) is one of the physiologic changes during laparoscopic surgery, which is known to be associated with positional changes. Changes of ICP can be measured directly by invasive method, but ultrasonographic measurement of optic nerve sheath diameter (ONSD) is known to be a rapidly applicable technique for evaluating ICP. The aim of this study is to i...
متن کامل