Changes in the effect of propofol in response to altered plasma protein binding during normothermic cardiopulmonary bypass.

نویسندگان

  • E Takizawa
  • H Hiraoka
  • D Takizawa
  • F Goto
چکیده

BACKGROUND During normothermic cardiopulmonary bypass (CPB), the effect on propofol pharmacokinetics of changes in its binding to plasma proteins is consistent with the predictions of the well-stirred model of hepatic elimination for nonrestrictively cleared drug. However, whether changes in binding lead to clinically significant changes in the drug effect remains unclear. The purpose of this study was to assess changes in the drug effect of propofol in response to altered plasma binding using quantitative EEG measurements. METHODS Thirty patients undergoing cardiac surgery were assigned randomly to receive propofol infusions at 4 (Group P-4) or 6 (Group P-6) mg kg(-1) h(-1) during surgery. The concentration of propofol in blood samples, collected from the radial artery at predetermined intervals, was determined by HPLC. The unbound fraction of drug in plasma was estimated using equilibrium dialysis. Bispectral index (BIS) and burst suppression ratio (BSR) were measured at the time blood samples were collected. RESULTS The total concentration of propofol in blood was unchanged during CPB relative to the pre-CPB value in both groups. However, the fraction of unbound propofol in blood increased by 2-fold during CPB. While BIS values were unchanged during CPB in Group P-4, there was a slight, but significant, decrease in Group P-6. In both groups, BSR significantly increased during CPB. BIS values showed a weak correlation with the concentration of unbound propofol (r(2)=0.19, P<0.001). BSR showed a moderate correlation with the concentration of unbound propofol (r(2)=0.56, P<0.001). CONCLUSIONS The anaesthetic effect of propofol significantly increased during CPB without any alteration in the total drug concentration. The enhanced efficacy may be caused by a reduction in plasma binding of the drug.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plasma propofol concentration and EEG burst suppression ratio during normothermic cardiopulmonary bypass.

BACKGROUND During cardiopulmonary bypass (CPB), several factors affect drug disposition and action. This topic has not been studied extensively during normothermic CPB. In this study, we related propofol dose to plasma propofol concentration and burst suppression of the EEG during normothermic bypass. METHODS After institutional approval and informed consent, 45 patients having cardiac surger...

متن کامل

Effects of isoflurane, sevoflurane and propofol anaesthesia on jugular venous oxygen saturation in patients undergoing coronary artery bypass surgery.

We investigated the effect of sevoflurane, isoflurane and propofol on jugular venous bulb oxygen saturation (SjO2) in 21 patients undergoing coronary artery bypass graft surgery (CABG) during and after normothermic cardiopulmonary bypass (CPB). Patients received a standardized anaesthetic consisting of fentanyl, midazolam and were then randomly allocated to receive either isoflurane, sevofluran...

متن کامل

Plasma proteomic changes during hypothermic and normothermic cardiopulmonary bypass in aortic surgeries

Deep hypothermic circulatory arrest (DHCA) is a protective method against brain ischemia in aortic surgery. However, the possible effects of DHCA on the plasma proteins remain to be determined. In the present study, we used novel high‑throughput technology to compare the plasma proteomes during DHCA (22˚C) with selective cerebral perfusion (SCP, n=7) to those during normothermic cardiopulmonary...

متن کامل

Comparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries

Background: This study compared the effect of Voluven and Ringer solution in cardiopulmonary bypass on the bleeding after the surgery and renal function in coronary artery bypass graft surgeries. Methods: Two types of prime solution including ringer - as Crystalloid- and Voluven were used in two groups and compared in terms of bleeding and renal function during the first 24 hours after the surg...

متن کامل

The Effect of ringer Lactate as the Priming Solution of the Cardiopulmonary by Pass Circuit on Plasma Potassium Levels after Open Heart Surgery in Children

Background: Conduct of cardiopulmonary bypass (CPB) due to the higher volume of priming solution in comparison to the total blood volume in children requires careful consideration. Recently attention has been focused on the potential risk of hyperkalemia in these patients. Given its significant effects on cardiac rhythm, hyperkalemia is considered a medical emergency. In this cross-sectional st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 96 2  شماره 

صفحات  -

تاریخ انتشار 2006