Detecting changes in serial myocardial perfusion SPECT: a simulation study.

نویسندگان

  • Tracy L Faber
  • Jan Modersitzki
  • Russell D Folks
  • Ernest V Garcia
چکیده

BACKGROUND New algorithms were evaluated for their efficacy in detecting and quantifying serial changes in myocardial perfusion from single photon emission computed tomography (SPECT). METHODS AND RESULTS We generated 72 simulations with various left ventricular positions, sizes, count rates, and perfusion defect severities using the nonuniform rational B-splines (NURBs)-based CArdiac Torso (NCAT) phantom. Images were automatically aligned by use of both full linear and rigid transformations and quantified for perfusion by use of the CEqual program. Changes within a given perfusion defect were compared by use of a Student t test before and after registration. Registration approaches were compared by use of receiver operating characteristic analysis. Changes of 5% were not detected well in single patients with or without alignment. Changes of 10% and 15% could be detected with false-positive rates of 15% and 10%, respectively, in single studies if alignment was performed before perfusion analysis. Alignment also reduced the number of studies necessary to demonstrate a significant perfusion change (P < .05) in groups of patients by about half. CONCLUSION Comparison of mean uptake by t values in SPECT perfusion defects can be used to detect 10% and greater differences in serial perfusion studies of single patients. Image alignment is necessary to optimize automatic detection of perfusion changes in both single patients and groups of patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Filter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]

Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, wh...

متن کامل

The evaluation of slant hole collimator in myocardial perfusion SPECT: a simulation study

Introduction: We have investigated cardiac SPECT with slant hole collimator in which the holes are slanted towards the target organ, to provide greater sensitivity over the parallel hole collimator. In addition, parallel hole collimator was used to obtain a comparison in FWHM, sensitivity, Compton and photoelectric area values in the simulations. Materials and Methods...

متن کامل

Complications after dipyridamole infusion in myocardial perfusion SPECT and correlation with homodynamic changes [Persian]

Introduction: In Iran dipyridamole is the main agent used for coronary dilatation before myocardial perfusion SPECT. This study tries to evaluate the side effects after dipyridamole infusion and its relation with hemodynamic changes. Methods: We studied 300 patients who referred to myocardial perfusion scan. The exclusion criteria were: 1) AV block degree 2 or more, 2) Asthma 3) Sick sinu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 2005