Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of H p (3) monitoring. A 2015 review.

نویسندگان

  • Eleftheria Carinou
  • Paolo Ferrari
  • Olivera Ciraj Bjelac
  • Merce Gingaume
  • Marta Sans Merce
  • Una O'Connor
چکیده

A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Status of eye lens radiation dose monitoring in European hospitals.

A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monito...

متن کامل

First Eurados Intercomparison Exercise of Eye Lens Dosemeters for Medical Applications.

In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of ...

متن کامل

Influence of dosemeter position for the assessment of eye lens dose during interventional cardiology.

The equivalent dose limit for the eye lens for occupational exposure recommended by the ICRP has been reduced to 20 mSv y(-1) averaged over defined periods of 5 y, with no single year exceeding 50 mSv. The compliance with this new requirement could not be easy in some workplace such as interventional radiology and cardiology. The aim of this study is to evaluate different possible approaches in...

متن کامل

International project on individual monitoring and radiation exposure levels in interventional cardiology.

Within the Information System on Occupational Exposure in Medicine, Industry and Research (ISEMIR), a new International Atomic Energy Agency initiative, a Working Group on interventional cardiology, aims to assess staff radiation protection (RP) levels and to propose an international database of occupational exposures. A survey of regulatory bodies (RBs) has provided information at the country ...

متن کامل

B-scan ultrasonography of ocular abnormalities: a review of 182 dogs

Ultrasonography is the only practical method for obtaining images of the posterior segment of the eye when the light-conducting media are opaque. In this study, 182 dogs with ocular abnormalities presented to the Department of Veterinary Surgery and Radiology from December 2008-August 2010 were included. All the animals were subjected to detailed ophthalmic examination and B-scan ultrasonograph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiological protection : official journal of the Society for Radiological Protection

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 2015