Volumetric dimensional change of six direct core materials.

نویسندگان

  • Supattriya Chutinan
  • Jeffrey A Platt
  • Michael A Cochran
  • B Keith Moore
چکیده

OBJECTIVES This study evaluated the influence of water on the volumetric dimensional change of six direct placement core build-up materials by using Archimedes' principle. METHODS The effect on dimensional change due to the setting reaction was determined through the use of a silicone oil storage medium. The materials used were two dual-cured resin composites (CoreStore and Build-It FR), two chemically activated resin composites (CorePaste and Ti-Core), one metal-reinforced glass ionomer cement (Ketac-Silver), and one resin-modified glass ionomer (Fuji II LC Core). Using the manufacturers' instructions for each material, cylindrical specimens were prepared with dimensions of 7+/-0.1 mm in diameter and 2+/-0.1 mm in height. Each material had four groups (n = 5) based on storage conditions; silicone oil at 23 and 37 degrees C and distilled water at 23 and 37 degrees C. A 0.01 mg resolution balance was used to determine volumetric dimensional change using an Archimedean equation. Measurements were made 30 min after mixing, and at the time intervals of 1, 14, and 56 days. RESULTS All materials exhibited dimensional change. Ketac-Silver had the most shrinkage in silicone oil and Fuji II LC showed the highest expansion in distilled water. The glass ionomer materials showed more change than did any of the resin composite materials. SIGNIFICANCE Current direct placement core materials show variation in the amount of volumetric dimensional change seen over a period of 56 days.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests

Objective To evaluate solubility, dimensional stability, filling ability and volumetric change of root-end filling materials using conventional tests and new Micro-CT-based methods. Material and Methods 7. Results The results suggested correlated or complementary data between the proposed tests. At 7 days, BIO showed higher solubility and at 30 days, showed higher volumetric change in compa...

متن کامل

A Comparative Study on the Dimensional Change of the Different Denture Bases

Statement of problem. Acrylic resin is most commonly used for denture bases. However, acrylic resin has week points of volumetric shrinkage during polymerization that reduces denture fit. The expandability of POSS (Polyhedral Oligomeric Silsesquioxane) containing polymer could be expected to reduce the polymerization shrinkage of denture bases and would increase the adaptability of the denture ...

متن کامل

Effect of Impla Fix and Duralay Acrylic Resin Splinting Materials on Dimensional Changes of Direct Implant Impressions

Background and Aim: Making impression of several implants simultaneously for fabrication of dental prosthesis is challenging for many clinicians. Splinting can be performed for highly accurate impression making and better adaptation of prostheses. This study aimed to assess the effect of Impla and Duralay acrylic resin splinting materials on dimensional changes of direct implant impressions. ...

متن کامل

Three-dimensional Volumetric Ultrasonography of Enlarged Adrenal Gland in Dog

Objective: Detection and evaluation of adrenal glands are complex problems in conventional ultrasonography in dogs. Using three-dimensional (3D) ultrasonography (US) in adrenal gland volume evaluation can add new potential for further adrenal studies. Design: Descriptive study Animals: a total of 10 mix breed dogs Procedures: The dogs underwent two dimensional (2D) and 3D US of the adrenal g...

متن کامل

Modeling bubble-vortex interactions Modeling and simulation of multiple bubble entrainment and interactions with two dimensional vortical flows

1 Modeling bubble-vortex interactions Simulations of bubble entrainment and interactions with two dimensional vorti-cal flows are preformed using a Discrete Element Model (DEM). In this Eulerian-Lagrangian approach, solution to the carrier phase is obtained using direct numerical simulation whereas motion of subgrid bubbles is modeled using Lagrangian tracking. The volumetric displacement of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental materials : official publication of the Academy of Dental Materials

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 2004