Inconsistencies in the treatment planning process leading to dosimetric uncertainties may affect conclusions drawn from interinstitutional radiation oncology clinical trials. The purpose of this study was to assess the dosimetric uncertainties resulting from the process of reconstructing three-dimensional dose distributions from two-dimensional treatment plan information provided by participating institutions in a randomized clinical trial. This study was based on American College of Radiology Protocol #427, Locally Advanced Multi-Modality Protocol; a multi-institutional phase II randomized study involving radiation therapy for patients with inoperable non-small cell lung cancer. Several sources of dosimetric uncertainty were identified and analyzed, including image quality of hard-copy computed tomography (CT) images, slice spacing of CT scans, treatment position, interpretations of target volumes by radiation oncologists, the contouring of normal anatomic structures, and the use of common beam models for all dose calculations. Each source of uncertainty was investigated using a set of plans, with the ideal characteristics of digital images with 3-mm axial slice spacing and a flat couch, consisting of eight cases from Vanderbilt University Medical Center with electronically transferred CT data. The target volume DVH values were dependent on the additional uncertainty introduced by differences in delineation of the target volumes by the participating radiation oncologists. The DVH values for the lungs and heart were dependent on image quality and treatment position. Esophagus DVH values were not dependent on any of the sources of uncertainty. None of the structure DVH values were dependent on slice thickness or variations in the contouring of normal anatomic structures. Reconstruction of three-dimensional dose distributions from two-dimensional treatment plan information may be useful in cases for which digital CT data is not available or for historical data review. However, dosimetric accuracy will depend on image quality of the treatment planning CT data and consistency in the delineation of tumor volumes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

dimensional film dosimetry with GAFCHROMIC films for quality assurance and dosimetric verification of 3D conformal radiotherapy in the presence of heterogeneities

Introduction: The presence of heterogeneities such as air-filled cavities in the head and neck treatment fields region, may result in potential dosimetric disagreement because the losses of charged particle equilibrium. Most of treatments planning systems are not able to predict dose distribution of inhomogeneities region accurately. Therefore, dose calculation algorithms need to...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Effect of Bolus Frequency and Its Thickness in Postmastectomy Three-dimensional Conformal Radiotherapy on Skin Dose for Superposition Algorithm

Introduction: The postmastectomy radiotherapy uses bolus to improve the coverage close to the skin; however, it needs to be removed in case of severe skin toxicity. This study investigated the effect of bolus parameters (i.e., frequency and thickness) for the superposition algorithm on skin dose in postmastectomy three-dimensional conformal radiotherapy (3D-CRT). <str...

متن کامل

Study of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis

Background: This study evaluates dosimetric and spatial variations in inter&ndash;fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...

متن کامل

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -