Accuracy of Ultrasound-Guided and Non-ultrasound-Guided Botulinum Toxin Injection Into Cadaver Salivary Glands

نویسندگان

  • Jae In So
  • Dae Heon Song
  • Joo Hyun Park
  • Eunseok Choi
  • Jung Yoon Yoon
  • Yeonji Yoo
  • Myung Eun Chung
چکیده

OBJECTIVE To compare the accuracy of ultrasound (US)-guided and non-US-guided botulinum toxin (BTX) injection into the salivary glands (parotid and submandibular glands) of cadavers. METHODS Two rehabilitation physician injected dye into three sites in the salivary glands (two sites in the parotid gland and one site in the submandibular gland) on one side of each cadaver (one was injected on the right side, while the other was injected on the left side), using either a non-US-guided injection procedure based on superficial landmarks or a US-guided procedure. Orange dye was used for the US-guided procedure, and green dye was used for the blind procedure. Two physicians uninvolved with the injection procedures and who were blinded to the method of injection dissected the cadavers to identify whether the dye was accurately injected into each target site. RESULTS The accuracies of the blind and US-guided injections into the parotid gland were 79.17% and 95.83%, respectively. In the submandibular gland, the accuracies of the blind and US-guided injections were 50.00% and 91.67%, respectively. The difference in accuracy between the two procedures was statistically significant only in the submandibular gland (p=0.025). There were no significant differences in the accuracy of US-guided and non-US-guided injections between the two physicians for the two sites in the parotid gland (p=0.278 and p=0.146, respectively). CONCLUSION US-guided BTX injection into the submandibular gland offers significantly greater accuracy over blind injection. For the treatment of drooling by injecting BTX into the submandibular gland, clinicians should consider using US guidance for improved accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of sialorrhoea with ultrasound guided botulinum toxin type A injection in patients with neurological disorders.

OBJECTIVES To investigate the safety and efficacy of ultrasound guided botulinum toxin type A (BTX-A) injections into salivary glands for the treatment of sialorrhoea in patients with neurological disorders. METHODS The parotid and submandibular glands of 10 patients were injected with BTX-A using ultrasound guidance. Before injection, the baseline rate of salivation was assessed using a visu...

متن کامل

Ultrasound-guided injection of botulinum toxin A in the treatment of iliopsoas spasticity.

PURPOSE Intramuscular injection of botulinum toxin A (BTX-A) is a common treatment for iliopsoas muscle spasticity, but it is not easy to position the needle in this muscle without guidance. In this paper we describe an ultrasound-guided technique for the intramuscular injection of BTX-A to treat spasticity of the iliopsoas muscle. Its effectiveness was assessed in 10 patients. METHOD AND MAT...

متن کامل

Ultrasound-guided botulinum toxin injection: A simple in-office technique to improve tracheoesophageal speech in postlaryngectomy patients.

BACKGROUND Pharyngoesophageal spasm is a known entity to cause hypertonic/failed tracheoesophageal speech and is successfully treated by botulinum toxin A injection. However, success of botulinum toxin treatment is based on the accurate localization of the pharyngoesophageal segment. METHODS A 65-year-old man who had a laryngectomy using voice prosthesis with hypertonic speech underwent ultra...

متن کامل

A comparison of ultrasound guided corticosteroid injection vs ozone injection in grade 3 knee osteoarthritis

Background: Osteoarthritis (OA) is a degenerative disease that can cause pain and limited function. One of the non-surgical treatments is intra-articular ozone injection. This study aimed to compare the effect of ultrasound-guided corticosteroid injection with ozone injection in patients with grade 3 osteoarthritis of the knee. Methods: This randomized, double-blind, clinical trial was carried...

متن کامل

Brief review: piriformis syndrome: etiology, diagnosis, and management.

PURPOSE In this narrative review, we aim to provide the pathophysiology and diagnostic criteria of the piriformis syndrome (PS), an underdiagnosed cause of buttock and leg pain that can be difficult to treat. Based on existing evidence, frequencies of clinical features are estimated in patients reported to have PS. In view of the increasing popularity of ultrasound for intervention, the ultraso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 41  شماره 

صفحات  -

تاریخ انتشار 2017