Clinical evaluation of keratometry and computerised videokeratography: intraobserver and interobserver variability on normal and astigmatic corneas.
نویسندگان
چکیده
AIMS To evaluate intra- and interobserver variability in measurements on normal and astigmatic corneas with keratometry and computerized videokeratography. METHODS Keratometric readings with the 10 SL/O Zeiss keratometer and topographic maps with the TMS-1 were obtained by two independent examiners on 32 normal and 33 postkeratoplasty corneas. Inter- and intraobserver coefficients of variability (COR) for measurements of steep and flat meridian power and location, in addition to the magnitude of astigmatism, were assessed. RESULTS Compared with TMS-1, the 10 SL/O keratometer showed a superior repeatability in measuring normal corneas (intraobserver COR for keratometry and TMS-1 respectively: 0.22 and 0.30 D for steep meridian power; 0.18 and 0.44 D for flat meridian power; 0.26 and 0.40 D for astigmatism; 5 degrees and 26 degrees for steep meridian location; 5 degrees and 13 degrees for flat meridian location). Astigmatism intraobserver COR (0.20 D and 0.26 D for the two observers) and interobserver COR (0.28 D) of the keratometer for normal corneas was very good and not affected by observers' experience. Repeatability of the TMS-1 on normal corneas was found to be: (a) observer related, and (b) astigmatism related. A novice observer showed a much greater COR (1.62 D for astigmatism, 30 degrees for flat meridian location) compared with the experienced examiner (0.40 D for astigmatism, 13 degrees for flat meridian location). Higher deviation scores were observed for corneas with higher astigmatism. For the postkeratoplasty corneas, again the keratometer achieved superior reproducibility (astigmatism interobserver COR 1.12 D for keratometry, 4.06 D for TMS-1; steep meridian location interobserver COR 10 degrees for keratometry, 34 degrees for TMS-1). CONCLUSION Keratometric readings are more reproducible than topographic data both for normal and postkeratoplasty corneas. The two instruments should not be used interchangeably especially on highly astigmatic corneas. For the TMS-1, users with the same level of experience should be employed in clinical or experimental studies.
منابع مشابه
Comparison of keratometry and videokeratography after penetrating keratoplasty.
BACKGROUND As new methods for corneal curvature measurement have evolved, users of videokeratscopes need to know the practical limitations of these instruments. We assessed agreement between keratometry and videokeratography in measuring highly astigmatic corneas. METHODS Two independent examiners made three keratometric and videokeratographic measurements on each of 33 corneas after penetrat...
متن کاملبررسی پایایی درون مشاهدهگر و بین مشاهدهگر در ارزیابی هیستوپاتولوژیک لیکن پلان دهانی بر اساس معیارهای modified WHO
Background and Aims: In 1978 WHO (World health organization) formulated a histopathological definition for diagnosis of OLP (oral lichen planus). Previous studies showed that diagnosis of OLP with these criteria are not reproducible. In 2003 Van der Meij et al. represented new clinical and histopathologic definition for diagnosis of OLP known as modified WHO criteria. The purpose of this study ...
متن کاملA new photogrammetric method for quantifying corneal topography.
Attempts to describe normal corneal shape and to represent corneal topography by an array of discrete points have limited usefulness. A quantitative photogrammetric method that produces indices to describe corneal shape was developed. Four indices depict the departure of keratographic rings from circularity, and two indices express the trends and consistencies of all the rings from one keratogr...
متن کاملComparison of keratometric and topographic cylinder and axis measurements on normal corneas with low astigmatism.
PURPOSE To evaluate agreement in measurements of astigmatic axis power and location between keratometry and computer assisted videokeratography (corneal topography) on normal corneas with less than 1.50 D of idiopathic astigmatism. METHODS Keratometric readings with the 10 SL/O Zeiss ophthalmometer and corneal topographic maps with the TMS-1 were obtained by two independent examiners on 32 no...
متن کاملThe interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture
Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 82 6 شماره
صفحات -
تاریخ انتشار 1998