Tetrapolar Impedance Plethysmograph for assessing peripheral venous congestion

نویسندگان

  • P C Bolognini
  • C B Goy
  • M A Gómez López
  • M C Herrera
چکیده

It has been suggested that venous congestion would be an independent and fundamental stimulus for the onset of decompensated cardiac heart failure. Early detection of congestion could be assessed by venous occlusion plethysmography. In this context, we propose to develop a tetrapolar impedance plethysmograph and method for evaluating the drain venous capacity after a 60sec cuff occlusion by analyzing changes in limb impedance. Occlusion maneuver avoids venous return; therefore, blood accumulates in limbs changing its impedance. The device comprises of a 50KHz stabilized current generator that provides a sinusoidal current of 2mA that flows through the limb to produce an amplitude modulated voltage which is appropriately amplified and filtered. Then, the signal is demodulated and stored using a sample and hold circuit. Finally, the basal impedance is separated from impedance variations due to volume changes by means of a suppression circuit. The whole plethymograph has proven to be highly linear (R 2 = 0.998) while the current shows stability in repeated measurements with different loads (from 6 to 412 Ω). Frequency response curve shows a typical low-pass pattern with a cut-off frequency of 7Hz. Finally, as an example, a temporary record of an occlusive maneuver in a healthy volunteer is presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of short-term venous congestion on forearm venous volume and reactive hyperemia blood flow in human subjects.

Congestive heart failure is associated with a reduction in limb venous volume at an effective venous pressure of 30 mm Hg (VV[30]). Further, an attenuated arteriolar dilation in response to a metabolic stimulus has been demonstrated. It was the purpose of this study to determine to what extent the chronic elevation in venous pressure seen in heart failure might explain these abnormalities of th...

متن کامل

Validation of tetrapolar bioelectrical impedance method to assess human body composition.

This study was conducted to validate the relationship between bioelectrical conductance (ht2/R) and densitometrically determined fat-free mass, and to compare the prediction errors of body fatness derived from the tetrapolar impedance method and skinfold thicknesses, relative to hydrodensitometry. One-hundred and fourteen male and female subjects, aged 18-50 yr, with a wide range of fat-free ma...

متن کامل

Changes in forearm blood flow during single and intermittent cold application.

STUDY DESIGN Two-factor repeated measures design. OBJECTIVES To compare the effects of a 20-minute cold application to the effects of a 20-minute cold application followed by 20 additional minutes of intermittent cold on forearm blood flow over a 60-minute period. BACKGROUND The appropriate duration of cold application as a therapeutic modality following soft tissue trauma is an important c...

متن کامل

Peripheral blood flow in secundum-type atrial septal defect; preoperative and postoperative studies.

The purpose of this study was to correlate intracardiac shunt and peripheral blood flow measured by a venous-occlusion plethysmograph in 30 patients with secundum-type atrial septal defects. Preoperative and postoperative blood flows in the forearm were expressed as milliliters per minute per 100 gm of tissue. Peripheral flow increased after closure of the atrial septal defect, except in seven ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011