Collision cross sectional areas from analysis of Fourier transform ion cyclotron resonance line width: a new method for characterizing molecular structure.

نویسندگان

  • Fan Yang
  • Jacob E Voelkel
  • David V Dearden
چکیده

We demonstrate a technique for determining molecular collision cross sections via measuring the variation of Fourier transform ion cyclotron resonance (FTICR) line width with background damping gas pressure, under conditions where the length of the FTICR transient is pressure limited. Key features of our method include monoisotopic isolation of ions, the pulsed introduction of damping gas to a constant pressure using a pulsed leak valve, short excitation events to minimize collisions during the excitation, and proper choice of damping gas (Xe is superior to He). The measurements are reproducible within a few percent, which is sufficient for distinguishing between many structural possibilities and is comparable to the uncertainty in cross sections calculated from computed molecular structures. These techniques complement drift ion mobility measurements obtained on dedicated instruments. They do not require a specialized instrument, but should be easily performed on any FTICR mass spectrometer equipped with a pulsed leak valve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective parent ion axialization for improved efficiency of collision-induced dissociation in laser desorption-ionization fourier transform ion cyclotron resonance mass spectrometry.

We have systematically established the excitation frequency, amplitude, duration, and buffer gas pressure for optimal axialization efficiency and mass selectivity of quadrupolar excitation-collisional cooling for isolation of parent ions for collision-induced dissociation in Fourier transform ion cyclotron resonance mass spectrometry. For example, at high quadrupolar excitation amplitude, ion a...

متن کامل

Direct Analysis in Real Time (DART) of an Organothiophosphate at Ultrahigh Resolution by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Tandem Mass Spectrometry

Direct analysis in real time (DART) is a recently developed ambient ionization technique for mass spectrometry to enable rapid and sensitive analyses with little or no sample preparation. After swab-based field sampling, the organothiophosphate malathion was analyzed using DART-Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) and tandem mass spectrometry (MS/MS). Mass r...

متن کامل

Surface-induced dissociation of ions produced by matrix-assisted laser desorption/ionization in a fourier transform ion cyclotron resonance mass spectrometer.

Intermediate pressure matrix-assisted laser desorption/ionization (MALDI) source was constructed and interfaced with a 6-T Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) specially configured for surface-induced dissociation (SID) studies. First MALDI-SID results in FT-ICR are presented, demonstrating unique advantages of SID over conventional FT-ICR MS ion activation te...

متن کامل

Direct screening of a dynamic combinatorial library using mass spectrometry.

A dynamic combinatorial library (DCL) screening approach is described that permits direct identification of the effective (from ineffective) combination of building blocks in the equilibrating DCL. The approach uses Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) together with sustained off-resonance irradiation collision activated dissociation (SORI-CAD) to detect noncov...

متن کامل

Dissociation of heme from gaseous myoglobin ions studied by infrared multiphoton dissociation spectroscopy and Fourier-transform ion cyclotron resonance mass spectrometry.

Detachment of heme prosthetic groups from gaseous myoglobin ions has been studied by collision-induced dissociation and infrared multiphoton dissociation in combination with Fourier-transform ion cyclotron resonance mass spectrometry. Multiply charged holomyoglobin ions (hMbn+) were generated by electrospray ionization and transferred to an ion cyclotron resonance cell, where the ions of intere...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 11  شماره 

صفحات  -

تاریخ انتشار 2012