Rotational Alignment of the Femoral Component in Computer-Assisted Total Knee Arthroplasty

نویسنده

  • Mark G. Clatworthy
چکیده

This study compared two Computer Assisted Surgery (CAS) methods in 212 total knee arthroplasties to evaluate the differences between anatomic landmark axes in determining rotational position of the femoral component. Overall, there were large variations between CAS defined component orientation using an optimized gap-balancing technique and component orientation using anatomic reference axes (range, 16o internal rotation to 16o external rotation). If based on anatomic landmarks, these large variations would have led to asymmetrical flexion gaps in up to 60% of the knees studied. Of the anatomic axes studied, the posterior condylar axis was the only axis not significantly different from CAS optimized orientation. If anatomic landmarks are used for femoral component rotation with either a conventional or a CAS technique, asymmetric trapezoidal flexion gaps may result.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.

INTRODUCTION A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was con...

متن کامل

Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty

BACKGROUND Accurate femoral rotational alignment is of vital importance for successful total knee arthroplasty (TKA). The value of computer-assisted surgery TKA (CAS-TKA) in increasing the accuracy of femoral rotational alignment remains controversial. We hypothesize that outcomes are related to the severity of preoperative varus and valgus deformity and that CAS-TKA may be beneficial under cer...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Component position alignment with patient-specific jigs in total knee arthroplasty.

BACKGROUND The failure to restore mechanical alignment and appropriate rotational axis intraoperatively has been described as one of the most common causes of implant failure in total knee arthroplasty (TKA). Both conventional and computer-assisted TKA have their limitations. Patient-specific jigs (PSJ) offer a possible alternative method for TKA. The aim of this study was to investigate if the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014