Some problems associated with assay of 25-hydroxycalciferol in human serum.
نویسندگان
چکیده
Methods available for the assay of 25-hydroxycalciferol in human serum are evaluated and compared to one another. Ethanol was chosen for use in the initial extraction procedure and rat-kidney cytosol as the binding protein, although good alternative methods are also available. We used silicic acid for chromatography and found this an essential step. Reproducibility was increased when, after "bound" and "free" material were separated, an aliquot of the supernate was pipetted into the counting vial instead of the entire supernatant fluid being decanted. Beta-lipo-protein added to the assay system was of no advantage; added bovine serum albumin interfered with the assay by giving rise to high blank values. With ethanol extraction, silicic acid chromatography, rat kidney cytosol and separation on dextran-coated charcoal, sera from normal subjects showed a mean 25-hydroxycalciferol concentration of 28.5 microng/liter (range, 13.1 to 43.9) during the fall season. Coefficients of variation for a control serum were 4.9% (intra-assay) and 10.9% (interassay).
منابع مشابه
Preparation of prostate specific antigen standards for immunoradiometric assay
Background: Immunoradiometric assay is one of the most common and precise methods for determination of prostate specific antigen (PSA) in clinical laboratories. Usual use of human serum in routine assays has many disadvantages such as easy contamination and precipitation, instability and unavailability. Thus in order to avoid these problems the artificial matrix was used which acts sim...
متن کاملDetermination of vitamin D status by radioimmunoassay with an 125I-labeled tracer.
We report here the first radioimmunoassay for a vitamin D metabolite utilizing a radioiodinated tracer. Antibodies were generated in a goat immunized with the vitamin D analog 23, 24, 25, 26, 27-pentanor-C(22)-carboxylic acid of vitamin D, coupled directly with bovine serum albumin. The 125I-labeled tracer was prepared by reacting a 3-amino-propyl derivative of vitamin D-C(22)-amide with Bolton...
متن کاملCytotoxicity of ICD-85 NPs on Human Cervical Carcinoma HeLa Cells through Caspase-8 Mediated Pathway
The biological application of nanoparticles (NPs) is a rapidly developing area of nanotechnology that raises new possibilities in the treatment of human cancers. The cytotoxicity was evaluated by MTT and LDH assays. The apoptotic effect of free ICD-85 and ICD-85 NPs on HeLa cells was assessed using caspase-8 colorimetric assay. The MTT assay showed that ICD-85 NPs could enhance the in-vitro cyt...
متن کاملCytotoxicity of ICD-85 NPs on Human Cervical Carcinoma HeLa Cells through Caspase-8 Mediated Pathway
The biological application of nanoparticles (NPs) is a rapidly developing area of nanotechnology that raises new possibilities in the treatment of human cancers. The cytotoxicity was evaluated by MTT and LDH assays. The apoptotic effect of free ICD-85 and ICD-85 NPs on HeLa cells was assessed using caspase-8 colorimetric assay. The MTT assay showed that ICD-85 NPs could enhance the in-vitro cyt...
متن کاملPreparation of an artificial matrix to replace human standards of prostate specific antigen IRMA assay kit [Persian]
Introduction: Prostate specific antigen (PSA) is one of the most sensitive markers for diagnosis of prostate cancer. Immunoradiometric kit (IRMA) is a common and sensitive method for determination of PSA in clinical laboratories. This kit has four major components: solid phase coated with monocolonal antibody, pair antibody labelled with I-125, series of standards i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 23 5 شماره
صفحات -
تاریخ انتشار 1977