Preservation of urine for flow cytometric and visual microscopic testing.
نویسندگان
چکیده
BACKGROUND Preservatives that could prevent destruction of cells, casts, and bacteria in urine are of great practical importance because they allow centralization and improvement of accuracy of urine particle counting. We compared two in-house mixtures and one commercial solution, as well as refrigeration, for their ability to preserve urine for both automated analysis (flow cytometry) and visual microscopy. METHODS Urine specimens were preserved by refrigeration at 4 degrees C without preservatives (procedure 1); in a lyophilized solution intended to preserve specimens for bacterial culture (Urine C&S tubes; BD Preanalytical Solutions; procedure 2); in 10 mL/L formalin-0.15 mol/L NaCl (procedure 3); in 80 mL/L ethanol-20 g/L polyethylene glycol (procedure 4); and by storage at 20 degrees C without preservatives (procedure 5). Test strip measurements were used to select specimens positive for leukocyte esterase, hemoglobin, albumin, or nitrite. For 106 consecutive strip-positive specimens, urinalysis was performed by UF-100 (Sysmex) and by phase-contrast microscopy after Sternheimer supravital staining. Automated analysis was performed at arrival in the morning, on the same day in the afternoon, and after 1 and 3 days. Visual microscopy was performed at arrival and 3 days later. RESULTS Urine bacterial counts were well preserved with procedures 1-3, with a false-positive rate of 0.0-3.4% at day 3 vs 28% without preservation (procedure 5). Erythrocytes were poorly preserved for 3 days (kappa coefficients, 0.24-0.61); after 1 day, fair preservation was seen with procedure 2 (kappa = 0.78), compared with less favorable preservation with procedure 1 (kappa = 0.61) or procedure 5 (kappa = 0.66). Leukocytes were well preserved by all five procedures in the acidic adult urines investigated. Counts of casts and large epithelial cells were artifactually increased by procedure 3. Procedure 2 performed at least as well as refrigeration for specimens analyzed with visual microscopy. CONCLUSIONS Urine specimens from adults can be stabilized at room temperature for both automated particle analysis and visual microscopy.
منابع مشابه
Quantitative Determination of Plasmodium Parasitemia by Flow Cytometry and Microscopy
The traditional light microscopy has limitations for precise growth assays of malaria parasites in culture or for assessment of new compounds for antimalarial activity; the speed and high reproducibility of flow cytometry can overcome these limitations. A flow cytometric method using PicoGreen, a DNA-binding fluorochrome, was developed with optimal precision suitable for performing growth assay...
متن کاملAutomated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.
BACKGROUND Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. METHODS A total of 3...
متن کاملComparison of Two Flow Cytometric Methods for Detection of Human Invariant Natural Killer T Cells (iNKT)
Background: Invariant natural killer cells (iNKT) are an important immunoregulatory T cell subset. Currently several flow cytometry-based approaches exist for the identifi-cation of iNKT cells, which rely on using the 6B11 monoclonal antibody or a combina-tion of anti-Vα24 and anti-Vβ11 antibodies. Objective: The aim of this study was to compare the ability of two flow cytometry-based methods f...
متن کاملFlow Cytometric Measurement of CD41/CD61 and CD42b Platelet Receptors and Clotting Assay of Platelet Factor 3 During Long Term-Storage of Platelet Concentrates
Background: The purpose of the present in vitro study was to evaluate the effect of long term storage of conventional platelet concentrates (PCs) on major platelet receptors CD42b and CD41/CD61 by flow cytometry method and also measuring the overall platelet procoagulant activity status using platelet factor 3 (PF3) assay. Materials and Methods: Six random units of conventional platelet conce...
متن کاملبررسی ارزش تشخیصی ردیابی جهشBRAF V600Eدربیماران ایرانی مبتلابه لوسمی سلول مویی
Abstract Background & Aims:BRAF-V600E mutation has recently been considered as a molecular marker in diagnosis of Hairy Cell Leukemia (HCL). Detection of this mutation has found a diagnostic and therapeutic value. The aim of the present study was comparing the diagnostic value of BRAF V600E mutation detection with other previous methods in diagnosis of HCL patients. Materials & M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 48 6 Pt 1 شماره
صفحات -
تاریخ انتشار 2002