Respiratory muscle pacing with chronically implanted intramuscular Permaloc electrodes: A feasibility study.

نویسندگان

  • James S Walter
  • Robert D Wurster
  • Qianlong Zhu
  • Franco Laghi
چکیده

We tested the feasibility of stimulating upper-intercostal and abdominal muscles plus the diaphragm by using chronically implanted intramuscular electrodes.During two survival surgeries with six dogs, intramuscular electrodes were implanted bilaterally in the three respiratory muscles. Standard stimulation of the diaphragm was conducted. The dorsolateral and ventrolateral abdominal wall areas were stimulated with a 25 mA current. The second to fourth intercostal spaces were stimulated to elicit the largest tidal volume associated with the least coactivation of the serratus and latissimus muscles. Lone diaphragm and upper-intercostal muscle pacing produced inhaled tidal volumes (mean +/- standard error of the mean) of 293 +/- 36 mL and 59 +/- 17 mL, respectively. Lone abdominal muscle pacing produced an exhaled volume of 55 +/- 17 mL. Combined pacing of diaphragm and intercostal muscles increased the inhaled volume to 389 +/- 39 mL. The addition of abdominal pacing following the combined stimulation of diaphragm and intercostals increased the exhaled volume to 472 +/- 54 mL. During autopsy, dislodgement of the electrodes overlying the ribs was a concern and probably resulted from loose animal jackets. Chronic intramuscular Permaloc electrodes can be implanted in several respiratory muscles and increase tidal volumes more than diaphragm stimulation alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory responses to stimulation of abdominal and upper-thorax intercostal muscles using multiple Permaloc electrodes.

Stimulation of abdominal and upper-thoracic muscles was studied with the long-term goal of improved respiratory care for spinal cord injury (SCI) patients. A 12-channel stimulator and multiple surface and implanted Permaloc electrodes were evaluated in five anesthetized canines. Abdominal stimulation with 100 mA using four bilateral sets of surface electrodes placed on the midaxillary line at t...

متن کامل

Identification of unexpected respiratory abnormalities in patients with amyotrophic lateral sclerosis through electromyographic analysis using intramuscular electrodes implanted for therapeutic diaphragmatic pacing.

BACKGROUND Amyotrophic lateral sclerosis patients have significant respiratory abnormalities with incomplete understanding of respiratory control. This study analyzes electromyography (EMG) of the diaphragm (dEMG) using implanted diaphragm pacing (DP) electrodes. METHODS Retrospective analysis of dEMG data were obtained during Institutional Review Board and US Food and Drug Administration app...

متن کامل

Referred shoulder pain (C4 dermatome) can adversely impact diaphragm pacing with intramuscular electrodes.

Diaphragm pacing is an alternative to mechanical ventilation in patients with high cervical cord damage (>C4 dermatome). It brings clinical benefits and reduces health costs [1–3]. It is also indicated in certain cases of central hypoventilation [4]. Two types of diaphragm pacing devices are commercially available. With intrathoracic phrenic stimulation, electrodes are implanted around the phre...

متن کامل

Ultrasound-guided insertion of intramuscular electrodes into suboccipital muscles in the non-human primate.

The head-neck system is highly complex from a biomechanical and musculoskeletal perspective. Currently, the options for recording the recruitment of deep neck muscles in experimental animals are limited to chronic approaches requiring permanent implantation of electromyographic electrodes. Here, we describe a method for targeting deep muscles of the dorsal neck in non-human primates with intram...

متن کامل

Electrodes for Direct Bladder Stimulation

Purpose: A bladder control system for spinal cord injured (SCI) patients is needed that can be implanted with minimally invasive methods. New Permaloc bipolar electrodes consisting of 6 mm helical, wire, stimulating surfaces separated by 3 mm and a polypropylene securing barb (Synapse Biomedical Inc) were developed for this application. They are implanted on the bladder wall with a 16 gauge nee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 48 2  شماره 

صفحات  -

تاریخ انتشار 2011