Marrow visualization on renal scintigraphy: an often-overlooked finding in azotemic patients.

نویسندگان

  • Anton Shapoval
  • Murthy Chamarthy
  • M Donald Blaufox
  • Leonard M Freeman
چکیده

UNLABELLED Delayed perfusion and enhanced hepatobiliary uptake are recognized findings on (99m)Tc-mercaptoacetyltriglycine ((99m)Tc-MAG3) scintigraphy in patients with renal insufficiency. Less well appreciated is the finding of bone marrow visualization. This study was performed to determine the frequency of this sign and to try to determine its association with laboratory parameters. METHODS We retrospectively studied medical records and the results of renal scans performed on 170 patients from June to December 2009 at the Montefiore Medical Center. Among them we identified 167 patients who fulfilled our inclusion criteria for participation in this study. Prominent individual vertebrae and sacroiliac joints were categorized as bone marrow visualization. A lack of radiotracer activity in individual vertebrae or in the sacroiliac joints was categorized as bone marrow nonvisualization. The studies were interpreted by 2 nuclear medicine physicians who were unaware of the laboratory and clinical data. RESULTS The 167 patients fulfilling our inclusion criteria were divided into 2 groups: group 1 (n = 20), with visualization, and group 2 (n = 147), without visualization. The mean creatinine level in group 1 was higher than that in group 2 (3.2 vs. 1.1, P = 0.001). There was no difference in mean hematocrit and hemoglobin between the 2 groups. None of the patients with a creatinine level less than 1.5 mg/dL had bone marrow visualization, whereas bone marrow was visualized in 44% of patients with a creatinine level greater than 1.5 mg/dL. There was no definite correlation between the intensity of marrow activity and the level of creatinine. CONCLUSION Bone marrow often may be visualized on early images of (99m)Tc-MAG3 renal scans of azotemic patients. The etiology needs further clarification. Enhanced marrow perfusion, an increased blood concentration of (99m)Tc-MAG3, and marrow hyperplasia secondary to associated anemia or hemolysis are possible causes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pancake kidney: An unusual type of renal fusion anomaly found in 99mTc-DMSA renal scintigraphy

A 2.5-year-old boy with a history of the previous incidental finding of an ectopic kidney in ultrasonography was referred to our nuclear medicine center for 99mTc-DMSA renal scintigraphy. The scan showed an unusual type of ectopic fused kidneys on the right side of the lower abdomen. In this anomaly, kidneys were fused completely across the medial portion of both upper and lower pole...

متن کامل

"Hot spot" on hepatic scintigraphy [Persian]

Filling defects are often observed on 99mTc sulfur colloid liver scans. Hot spots are much less frequently seen. Superior vena cava syndrome is the most frequent cause of this finding. In this report 3 patients with S.V.C and budd - Chiari syndrome with HOT SPOT on liver scan are presented. Mechanisms of scintigraphic patterns are reviewed.

متن کامل

Diuretic effect on the measurement of differential renal function using 99mTc-DMSA in patients with hydronephrosis [Persian]

Introduction: It has been suggested that calculation of differential renal function (DRF) using 99mTc-DMSA may lead to overestimation of the function of an obstructed kidney. The aim of this study was to evaluate the effect of diuretic administration on the determination of DRF using 99mTc-DMSA scintigraphy in patients with dilated pelvis. Methods: Thirty three patients, aged from 2 month...

متن کامل

use of 99m Tc-DMSA scintigraphy in assessment of renal complications of COVID-19

 ABSTRACT COVID-19 mainly affects respiratory and immune systems, but other organs like renal, cardiovascular, lung and nervous systems could also be involved in both acute and chronic settings (1, 2). There is a lot of studies that demonstrate an increasing number of long COVID-19 who continue to experience persistent symptoms weeks or even months after the initial disease. Reports suggest...

متن کامل

Clinical significance of additional lateral imaging in diagnosis of prosthesis infection by combined Tc-99m labeled leukocyte/bone marrow scintigraphy

Introduction: Recently the most accurate diagnostic method in the diagnosis of prosthesis infection is the combination of Tc-99m labeled leukocyte/bone marrow imaging. However the diagnostic efficiency of the test is influenced because of its low spatial resolution. Recently SPECT/CT imaging is implicated in this test with efficient additional diagnostic improvement. In the dep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2011