A distributed equivalent magnetic current based FDTD method for the calculation of E-fields induced by gradient coils.
نویسندگان
چکیده
This paper evaluates a new, low-frequency finite-difference time-domain method applied to the problem of induced E-fields/eddy currents in the human body resulting from the pulsed magnetic field gradients in MRI. In this algorithm, a distributed equivalent magnetic current is proposed as the electromagnetic source and is obtained by quasistatic calculation of the empty coil's vector potential or measurements therein. This technique circumvents the discretization of complicated gradient coil geometries into a mesh of Yee cells, and thereby enables any type of gradient coil modelling or other complex low frequency sources. The proposed method has been verified against an example with an analytical solution. Results are presented showing the spatial distribution of gradient-induced electric fields in a multi-layered spherical phantom model and a complete body model.
منابع مشابه
Specific absorption rates and induced current densities for an anatomy-based model of the human for exposure to time-varying magnetic fields of MRI.
A 6-mm resolution, 30-tissue anatomy-based model of the human body is used to calculate specific absorption rate (SAR) and the induced current density distributions for radiofrequency and switched gradient magnetic fields used for MRI, respectively. For SAR distributions, the finite-difference time-domain (FDTD) method is used including modeling of 16-conductor birdcage coils and outer shields ...
متن کاملA New FDTD Method for the Study of MRI Pulsed Field Gradient- Induced Fields in the Human Body
In modern MRI, patients are exposed to strong, rapidly switched magnetic field gradients that may be able to elicit nerve stimulation (1-14). This paper provides the numerical results of an investigation into induced current spatial distributions inside human tissue when exposed to these pulsed magnetic field gradients. Conventional FDTD methods are unable to model these effects as the effectiv...
متن کاملFDTD Analysis of transient eddy currents induced by gradient coil switching in MRI
A. Trakic, H. Wang, F. Liu, H. S. Lopez, S. Crozier School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD, Australia Synopsis: Most Magnetic Resonance Imaging (MRI) spatial encoding techniques employ low-frequency pulsed magnetic field gradients that undesirably induce multi-exponentially decaying eddy currents in nearby conducting structures o...
متن کاملAnalytic Calculation of the E-Fields induced by Gradient Coil Switching
Introduction: Nerve stimulation induced by rapidly switching magnetic field gradients poses an upper limit on the gradient strengths that can be employed in fast magnetic resonance imaging and diffusion measurements’. The likelihood of stimulation is usually assessed by evaluation of the maximum rate of change of the magnetic field, inside the gradient coi12. Nerve stimulation actually occurs a...
متن کاملElectromagnetic Field Due to Lightning Strikes to Mountainous Ground
The produced electric and magnetic fields due to lightning strikes to mountainous ground are determined in this paper. For the sake of simplicity a cone-shaped ground with finite conductivity is assumed to represent a natural nonflat ground. By this assumption, we deal with an axillary symmetrical structure so we use the cylindrical 2D-FDTD to save the simulation memory and time, dramatically. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance
دوره 169 2 شماره
صفحات -
تاریخ انتشار 2004