Experimental Investigation of Beam Optics Issues at the Bremsstrahlung Converters for Radiographic Applications
نویسندگان
چکیده
As part of the Dual Axis Radiographic Hydrodynamic Test Facility II (DARHT II) and Advanced Hydrotest Facility (AHF) programs, we have began investigation of the possible adverse effects of (1) backstreaming ion emission from the Bremsstrahlung converter target and (2) the interaction of the resultant plasma with the electron beam during subsequent pulses. These effects would primarily manifest themselves in the static focusing system as a rapidly varying x-ray spot. To study these effects, we are conducting beam-target interaction experiments on the ETA-II accelerator (a 6.0 MeV, 2.5 kA, 70 ns FWHM pulsed, electron accelerator). From these experiments and the multiple diagnostics we have implemented, we are able to determine spot dynamics and characterize the resultant plasma for various configurations. Our data to date shows the first effect to be minimal. We report on the details of our experiments and our preliminary experiments to study the second effect.
منابع مشابه
Use of a Two-Channel Moiré Wavefront Sensor for Measuring Topological Charge Sign of the Vortex Beam and Investigation of Its Change Due to an Odd Number of Reflections
One of the solutions of the Helmholtz equation is the vortex beams. In the recent decades, production and applications of these types of beams have found serious attentions. Determination of the vortex beam topological charge and its sign are very important issues. Odd number of reflections of the vortex beam changes its vorticity. In this paper, we have used a q-plate to generate a vortex beam...
متن کاملSynthesis of TiO2-ZnO-ZrO2 Nanocomposites for Nonlinear Optics Applications
A sol-gel technique under ultrasonic irradiation was applied to synthesize ZrO2/TiO2/ZnOnanocomposites. X-ray diffraction analysis confirmed the successful synthesis of nanocomposites. The strain and crystalline size values of ZrO2/TiO2/ZnO nanocomposites are estimated to be 9.98×10-4 and 17.66 nm, respectively. The linear absorption coefficient of ZrO2/TiO2/ZnO nanocomposites was measure...
متن کاملAn assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method
Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...
متن کاملمحاسبه میزان دز پرتوهای ترمزی ناشی از الکترون ها در پرتو درمانی با الکترون در بیمارستان آیت ا...خوانساری اراک
During the radiation therapy with electron beam, due to electron interaction and scattering from structures of the head of the medical linear accelerator, unwanted photons are produced. The main contribution of the photon contamination is resulted from the various components of the medical linear accelerator on the way of the high energy electron beam, and few percent is due to the interaction ...
متن کاملInvestigation of the Effect of Electron Beam Different Doses on Optical Dissipation in Fiber Optic
Measurement of ionizing radiation in various fields, such as environmental safety, industrial detection processes, radiation protection and medical is very important. Radiation dosimetry plays an important role in determining the amount of energy absorbed and the effects of radiation. Recent optical fiber sensors have been shown to be radiation dosimeters. Our goal here is to investigate the ef...
متن کامل