A Biological Micro Actuator: Graded and Closed-Loop Control of Insect Leg Motion by Electrical Stimulation of Muscles

نویسندگان

  • Feng Cao
  • Chao Zhang
  • Tat Thang Vo Doan
  • Yao Li
  • Daniyal Haider Sangi
  • Jie Sheng Koh
  • Ngoc Anh Huynh
  • Mohamed Fareez Bin Aziz
  • Hao Yu Choo
  • Kazuo Ikeda
  • Pieter Abbeel
  • Michel M. Maharbiz
  • Hirotaka Sato
چکیده

In this study, a biological microactuator was demonstrated by closed-loop motion control of the front leg of an insect (Mecynorrhina torquata, beetle) via electrical stimulation of the leg muscles. The three antagonistic pairs of muscle groups in the front leg enabled the actuator to have three degrees of freedom: protraction/retraction, levation/depression, and extension/flexion. We observed that the threshold amplitude (voltage) required to elicit leg motions was approximately 1.0 V; thus, we fixed the stimulation amplitude at 1.5 V to ensure a muscle response. The leg motions were finely graded by alternation of the stimulation frequencies: higher stimulation frequencies elicited larger leg angular displacement. A closed-loop control system was then developed, where the stimulation frequency was the manipulated variable for leg-muscle stimulation (output from the final control element to the leg muscle) and the angular displacement of the leg motion was the system response. This closed-loop control system, with an optimized proportional gain and update time, regulated the leg to set at predetermined angular positions. The average electrical stimulation power consumption per muscle group was 148 µW. These findings related to and demonstrations of the leg motion control offer promise for the future development of a reliable, low-power, biological legged machine (i.e., an insect-machine hybrid legged robot).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonlinear Stabilizing Controller for a Special Class of Single Link Flexible Joint Robots

Joint flexibility is a very important factor to consider in the controller design for robot manipulators if high performance is expected. Most of the research works on control of flexible-joint robots in literature have ignored the actuator dynamics to avoid complexity in controller design. The problem of designing nonlinear controller for a class of single-link flexible-joint robot manipulator...

متن کامل

An efficient method to control the amplitude of the limit cycle in satellite attitude control system

In this paper, an efficient method is presented to control the attitude of a satellite with ON-OFF actuator. The main objective of this novel method is to control the amplitude of the limit cycle which commonly appears in the steady state of such systems; and at the same time by consideration of real actuator constraints, reduce the fuel consumption of system. The Proposed method is a combinati...

متن کامل

Control Reconfiguration of a Boiler-Turbine Unit After Actuator Faults

Boiler-turbines are one of the most important parts in power generation plants. The safety problem in such systems has always been a special concern. This paper discusses the application of control reconfig uration by fault-hiding approach for a boiler-turbine unit. In Fault-hiding approach, after occurrence of a fault, nominal controller of the system remains unchanged; instead, a reconfigurat...

متن کامل

Application of Piezoelectric and Functionally Graded Materials in Designing Electrostatically Actuated Micro Switches

In this research, a functionally graded microbeam bonded with piezoelectric layers is analyzed under electric force. Static and dynamic instability due to the electric actuation is studied because of its importance in micro electro mechanical systems, especially in micro switches. In order to prevent pull-in instability, two piezoelectric layers are used as sensor and actuator. A current amplif...

متن کامل

Optimizing control motion of a human arm With PSO-PID controller

Functional electrical stimulation (FES) is the most commonly used system for restoring function after spinal cord injury (SCI). In this study, we used a model consists of a joint, two links with one degree of freedom, and two muscles as flexor and extensor of the joint, which simulated in MATLAB using SimMechanics and Simulink Toolboxes. The muscle model is based on Zajac musculotendon actuator...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014