Evaluation of the tip-bending response in clinically used endoscopes.

نویسندگان

  • Esther D Rozeboom
  • Rob Reilink
  • Matthijs P Schwartz
  • Paul Fockens
  • Ivo A M J Broeders
چکیده

BACKGROUND AND STUDY AIMS Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current technique of endoscope tip control is adequate for a future of high precision procedures, steerable accessories, and add-on robotics. The aim of this study was to determine the status of the tip response of endoscopes used in clinical practice. MATERIALS AND METHODS We evaluated 20 flexible colonoscopes and five gastroscopes, used in the endoscopy departments of a Dutch university hospital and two Dutch teaching hospitals, in a bench top setup. First, maximal tip bending was determined manually. Next, the endoscope navigation wheels were rotated individually in a motor setup. Tip angulation was recorded with a USB camera. Cable slackness was derived from the resulting hysteresis plot. RESULTS Only two of the 20 colonoscopes (10 %) and none of the five gastroscopes reached the maximal tip angulation specified by the manufacturer. Four colonoscopes (20 %) and none of the gastroscopes demonstrated the recommended cable tension. Eight colonoscopes (40 %) had undergone a maintenance check 1 month before the measurements were made. The tip responses of these eight colonoscopies did not differ significantly from the tip responses of the other colonoscopes. CONCLUSION This study suggests that the majority of clinically used endoscopes are not optimally tuned to reach maximal bending angles and demonstrate adequate tip responses. We suggest a brief check before procedures to predict difficulties with bending angles and tip responses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a novel, ultrathin, tip-bending endoscope in a synthetic force-sensing pancreas with comparison to medical guide wires

PURPOSE Direct visualization of pancreatic ductal tissue is critical for early diagnosis of pancreatic diseases and for guiding therapeutic interventions. A novel, ultrathin (5 Fr) scanning fiber endoscope (SFE) with tip-bending capability has been developed specifically to achieve high resolution imaging as a pancreatoscope during endoscopic retrograde cholangiopancreatography (ERCP). This dev...

متن کامل

Numerical Investigation of Rail Bending Behaviour Focusing on the Effect of Track Modulus

Thorough understanding of steel rail response to wheel load is a key step towards design and evaluation of the railway track structure. In current practice, maximum vertical deflection and bending moment are calculated using the theory of infinite beam on continuous elastic foundation (Winkler model), in which the foundation stiffness is assumed as constant. However, variation of track modulus ...

متن کامل

Disposable endoscope tip actuation design and robotic platform Citation

A disposable endoscopic platform with actuation motors inside the body of the endoscope is presented. This platform can enable new medical devices for diagnosis and for minimally invasive surgeries. This paper addresses mechanical and safety issues with existing endoscope technologies by incorporating disposability, safety modules, and lower cable forces. In order to produce path-independent ca...

متن کامل

EXPERIMENTAL AND NUMERICAL INVESTIGATION ON LASER BENDING PROCESS

Laser bending is an advanced process in sheet metal forming in which a laser heat source is used to shape the metal sheet. In this paper, temperature distribution in a mild steel sheet metal is investigated numerically and experimentally. Laser heat source is applied through curved paths in square sheet metal parts. Finite element (FE) simulation is performed with the ABAQUS/CAE standard softwa...

متن کامل

Evaluation of Fatigue Properties of Asphalt Mixtures Containing Reclaimed Asphalt using Response Surface Method

This paper presents the effects of different amounts of reclaimed asphalt on fatigue life of asphalt mixtures. Central composite method was used to design of experiments based on response surface method (RSM). Binder type (Pen 60/70 and Pen 85/100), reclaimed asphalt pavement (RAP) content (25, 50 and 75%) and loading strain (150, 250 and 350 micro strain) were selected as independent variables...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy international open

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2016