Comparison of Software Models for Energy Savings from Cool Roofs

نویسنده

  • Joshua New
چکیده

A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings from reduced HVAC use. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy consumption. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results show reduced cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC’s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents the preliminary analyses. RSC’s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors toward slightly increased cooling savings offset by larger heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy savings in buildings or UHI mitigation? Comparison between green roofs and cool roofs

The intensification of the Urban Heat Island effect (UHI) is a problem that involves several fields, and new adequate solutions are required to mitigate its amplitude. The construction sector is strictly related with this phenomenon; in particular, roofs are the envelope components subject to the highest solar irradiance, hence any mitigation strategy should start from them and involve their ap...

متن کامل

Hydroponics Roofs for Saving Energy of Green Schools in the Cold and Dry climate of Iran: A Comparative Study between Two Broad and Modular Hydroponic Green Roofs

Green schools are a new type of school, in which the use of renewable energy is less than that of conventional schools. In this regard, nowadays, adding green layers to the roof of schools, in addition to increasing the Students' communication with nature, energy saving has improved in these spaces. However, to improve energy saving yield, the priority of these types of roofs in different clima...

متن کامل

Green Roofs in the Tropics Conserve Energy

Background: Concrete buildings on Guam are exceptionally strong but also accumulate large amounts of heat. In the tropical environment of Guam, where 24 h average temperature ranges from 28 to 29oC year round, air conditioning is used every day and continuously. Concrete roofs are often painted light colors, which make them more reflective and accumulate less heat. They are also suitable for es...

متن کامل

Energy Effects of Heat-Island Reduction Strategies in Toronto, Canada

The effect of heat-island reduction (HIR) strategies on annual energy savings and peak-power avoidance of the building sector of the Greater Toronto Area is calculated, using an hourly building energy simulation model. Results show that ratepayers could realize potential annual energy savings of over $11M from the effects of HIR strategies. The residential sector accounts for over half (59%) of...

متن کامل

ASTM Standards for Measuring Solar Reflectance and Infrared Emittance of Construction Materials and Comparing their Steady-State Surface Temperatures

Numerous experiments on individual buildings in California and Florida show that painting roofs white reduces air conditioning load up to 50%, depending on the thermal resistance or amount of insulation under the roof. The savings, of course, are strong functions of the thermal integrity of a building and climate. In earlier work, we have estimated the national energy savings potential from ref...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014